User Manual
Pure Line 1000 by Wagan Tech
®
15
www.wagan.com
TROUBLESHOOTING
PROBLEM: Low or No Output Voltage – Fault LED Lit
Reason Solution
Poor contact with battery, inverter
terminals.
Clean terminals thoroughly. Reinstall
and tighten.
PROBLEM: Inverter Auto Shut Down – Fault LED Lit
Reason Solution
Battery voltage is below 10.0 volts. Charge or replace battery.
Inverter is too hot (thermal shut down
mode).
• Allow inverter to cool.
• Check for adequate ventilation.
• Reduce the load on the inverter to
the specified TrueRated
™
power
max output.
PROBLEM: Inverter Shut Down – Fault LED Lit
Reason Solution
Equipment being operated draws too
much power.
Do not use the equipment with this
inverter; use a higher wattage inverter.
PROBLEM: Inverter Shut Down – Yellow LED Lit
Reason Solution
GFCI Tripped. Disconnect appliances. To reset, turn off
ON/OFF switch and turn back on.