14
CABLE GAUGES BASED ON ROUND TRIP CABLE LENGTHS
1,000W (Item No. 2294)
Input
Cable length
(feet)
8 9–10 11–14 15–17 18–21 22 23–25
Fuse*
(Amps)
12V
Gauge
(AWG)
6 4 2 2 2 0 0 120
24V
8 6 4 4 4 2 2 60
48V
10 8 6 6 6 4 4 30
1,500W (Item No. 2004)
Input
Cable length
(feet)
8 9–10 11–14 15–17 18–21 22 23–25
Fuse*
(Amps)
12V
Gauge
(AWG)
4 2 2 0 0 0 00
200
24V
6 4 4 2 2 2 0
100
48V
8 6 6 4 4 4 2
50
2,000W (Item No. 2482)
Input
Cable length
(feet)
8 9–10 11–14 15–17 18–21 22 23–25
Fuse*
(Amps)
12V
Gauge
(AWG)
2 2 0 0 00 000 000
250
24V
6 4 2 2 0 0 0
120
48V
6 6 4 4 2 2 2
60