User`s manual

www.wagan.com
©2012 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
User’s ManualRead before using this equipment
12
Keep the cables between the battery and the power inverter as short as
possible and twist them together with about 2 to 3 twists per foot. This
minimizes radiated interference from the cables.
Ferrite beads may be installed around battery cables and AC appliance
cords to reduce noise.
MAINTENANCE
Very little maintenance is required to keep the inverter operating properly.
Periodically check to ensure all terminals and connectors are secure and tight.
HEAT DISPERSAL
The inverter generates heat while it is working. This is not a malfunction. However,
if the inverter gets too hot while working, it will turn off by itself. Position the inverter
where air flows freely around it to allow the heat to disperse. The inverters thermal
protection prevents it from operating when its temperature exceeds 130ºF ± 10ºF
(55ºC ± 5ºC).
TROUBLESHOOTING
PROBLEM: Low or No Output Voltage – Fault LED Lit
Reason Solution
Poor contact with battery or inverter
terminals.
Clean terminals thoroughly. Reinstall
and tighten.
PROBLEM: Inverter Automatically Shut Down – Fault LED Lit
Reason Solution
Battery voltage below 10 Volts Charge or replace battery.
Inverter is too hot.
(Thermal protection mode.)
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the inverter to
rated continuous power output.
Unit may be defective. See warranty and call customer service.