User`s manual
Slim Line
™
Power Inverters by Wagan Tech
®
www.wagan.com
13
©2012 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
PROBLEM: Inverter Automatically Shut Down – Fault LED Lit – OVL Display
Reason Solution
Equipment being operated draws too
much power.
Use a higher capacity inverter or do
not use this equipment.
PROBLEM: Continuous Buzzing Sound – Display Shows Low Voltage
Reason Solution
Input voltage below 10.5 Volts . Keep input voltage above 10.5 Volts
Poor or weak battery condition. Recharge or replace battery.
Poor or loose cable connection. Inspect terminals and tighten all
connections.
Inadequate power being delivered to
the inverter or excessive voltage drop.
Use heavier gauge DC cable.
Keep cable length as short as possible.
DISPOSAL/RECYCLING OF INVERTER
Electronic products are known to contain materials that are toxic if improperly
disposed. Contact local authorities for disposal and recycling information.
SPECIFICATIONS
All specifications are typical at nominal line, half load and 77ºF (25ºC) unless
otherwise noted. Specifications are subject to change without notice.
Name Description
Input 12V (10V–15V) DC
Output 115V AC
Output frequency 60 Hz
Output waveform Modified Sine Waveform