6
power inverter. The only solution is to use a sound system that incorporates a
higher quality power supply.
Operating a Television
Picture tubes have a degaussing coil that uses a high initial surge of power to
light up the screen from a “cold start.” If the TV does not start up on the first
attempt, try to switch on the TV every 2 to 3 seconds until the screen comes on.
Sometimes, it may take 2 to 5 tries before starting.
Television Interference
Operating the power inverter can interfere with television reception on some
channels. If this situation occurs, the following steps may help to alleviate the
problem:
• Make sure that the chassis ground lug on the back of the power inverter
is solidly connected to the ground system of your vehicle.
• Do not operate high power loads with the power inverter while watching
television.
• Make sure that the antenna feeding your television provides an
adequate “snow free” signal and that you are using good quality cable
between the antenna and the television.
• Move the television as far away from the power inverter as possible.
• Keep the cables between the battery and the power inverter as short as
possible and twist them together with about 2 to 3 twists per foot. This
minimizes radiated interference from the cables.
MAINTENANCE
Very little maintenance is required to keep the inverter operating properly.
HEAT DISPERSAL
The inverter generates heat while it is working. This is not a malfunction.
However, if the inverter gets too hot while working it will turn off by itself.
Position the inverter where air flows freely around it to allow the heat to
disperse. The inverter’s thermal protection prevents it from operating when its
temperature exceeds 130ºF ± 10º (55ºC ± 5º).
TROUBLESHOOTING
Condition Solution
Poor contact Clean contact parts thoroughly
Battery voltage is too low Start the engine to recharge the
battery. Replace the battery if
needed.
Shutdown on overload Reduce the inverter’s wattage load
Thermal shutdown Allow the inverter to cool down by
reducing the load or turning it off for
a while.
Receptacle has no power Check the receptacle wiring.