• Audible Alarm (internal to the inverter): When the audible Alarm makes a buzzing sound,
the inverter senses a low battery condition. The user should reduce the AC load, charge the
battery, and check the DC cable or excessive losses.
• Ground Terminal: Grounding the Inverter Enclosure ensures personnel safety should a DC
cable problem occur. During the installation procedure, the Ground Terminal is connected
either to a vehicle chassis or to the Negative DC Terminal of the battery. Do not directly
connect this ground connection to the negative DC terminal of the inverter. Use an insulated
10 gauge wire to make the ground connection. If the inverter installation is located in fixed
location, the safety wire can be connected to earth’s ground.
Retractable Antenna
Retracted Antenna Extended Antenna
On Switch
Off Switch
Sliding Cap
Remote On/OFF Switch
This inverter is supplied with a 100-foot range battery-powered wireless remote ON/OFF feature.
To enable the Remote Switch, the front panel On/Off Switch must be in the On position.
To turn On the inverter, momentarily press ON. To turn the inverter Off, momentarily press “Lock”.
If the wireless remote fails to control operation of the inverter, you may be out of range for the
radio signal—move closer to the inverter. If the Remote Switch has a depleted battery, open the
unit by unscrewing the three small screws on the back side of the remote control and replace the