User`s manual
www.wagan.com
©2012 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
User’s Manual—Read before using this equipment
9
12V Battery Bank
Fuse
⚠ WARNING—Exploding Batteries!!
Exploding batteries can spray molten lead, hot sulfuric acid, and other metal and
plastic fragments. Batteries that are charging or under high discharge rates pro-
duce explosive hydrogen gas into the surrounding area. Be safe–fuse the battery
bank and make sure the batteries are properly ventilated.
DC CABLE GAUGE
Minimize cable losses by using the thickest wire available and the shortest practical length.
Measure Round Trip (RT) cable distances in feet. Round Trip cable distance is battery to inverter
and back to battery. If the application is in a vehicle with engine operating, use the supplied
cables for round trip distances up to 5 feet.
Use a recommended ANL fuse and Fuse holder. Fuse at 125 to 150 Amps. ANL are quick acting
and sealed so they do not spark when they blow. Place fuse no more than one foot from the Posi-
tive (+) terminal of the battery.
RT Length Up to 2 Ft 3-4 Ft 5-6 Ft 7-9 Ft 14-16 Ft
AWG 6 4 2 0 0
If the inverter and the battery are positioned within four feet of each other, a minimum of 7AWG
insulated copper wire should be used to make the connections. If the distance is longer than 32
inches (2.6 ft), heavier wire will be required.
CONNECTING THE INVERTER
Loose connections will result in a severe voltage drop that can cause damage to connectors, con-
ductors, and insulation and can cause sparking. Reverse polarity connection will blow the fuses in
24