CLEANUP
1
1/2
PULL
2
3
4
5
EMPTY WASTE
CONTAINER
6
1/2
PULL
FLUSHING THE UNIT
BEFORE YOU BEGIN
When cleaning, use the appropriate cleaning solution (warm, soapy water for latex
materials; mineral spirits for oil-based materials)
IMPORTANT: Never clean air cap or air holes in the nozzle with sharp metal
objects. Do not use solvents or lubricants containing silicone.
Special cleanup instructions for use with flammable solvents
(must have a flashpoint above 100ºF (38ºC):
Always ush spray gun outside.
Area must be free of ammable vapors.
Cleaning area must be well-ventilated.
Do not submerge turbine!
TO FLUSH THE UNIT
1. Turn turbine and handle switches to OFF (0) position. Unplug the power cord.
Loosen the material container by 1/2 turn, but do not remove it. This will relieve
any pressure left over in the system.
Pull the trigger so that the material inside the spray nozzle drains back into the
container.
2. Unscrew the container and remove. Empty any remaining material back into the
material container.
3. Pour a small amount of the appropriate cleaning solution into the cup (Water=1/2
full. Mineral spirits=1/4 full).
4. Attach the cup to the nozzle and plug in the turbine. Turn turbine and handle
switches to ON (I) position.
5. Spray the cleaning solution into a safe area. While spraying, gently shake the spray
gun. This slight agitation will help break up smaller particles of spray material.
6. Turn turbine and handle switches to OFF (0) position. Unplug the power cord.
Loosen the material container by 1/2 turn, but do not remove it. This will relieve
any pressure left over in the system.
Pull the trigger so that the material inside the spray nozzle drains back into the
container.
IMPORTANT: If you cleaned the sprayer using mineral spirits, repeat steps 1-6
using warm, soapy water.
Move on to “Cleanup - Cleaning the Nozzle”, next page.