User Manual

EN
13
CLEANUP (continued)
1
2a
(a)
(b)
2b 3a 4
(c)
5
(d)
(e)
NOZZLE SEAL CONTROL FINISH NOZZLE ONLY
*
The nozzle seal may become stuck
inside the Control Finish nozzle
when the nozzle is removed. If
this occurs, make sure to pull it
out.
**
It is important that the nozzle seal
inside the nozzle be re-installed
properly. Make sure the cup
side of the seal (the side with the
groove) is facing out towards the
front of the nozzle. Improper
installation will cause leakage and
damage to the turbine.
Groove
CLEANING THE NOZZLE
1. Make sure power cord is unplugged. Remove the air hose from the turbine.
2. iSpray nozzle only -
a. Remove the adjustment ring (a) carefully from the connecting nut (b). Loosen
the connecting nut.
b. Remove the parts as shown. Clean all parts with a cleaning brush and the
appropriate cleaning solution.
To reassemble, see the instructions on the next page.
3. Control Finish nozzle only -
a. Unscrew the nut and remove the air cap and nozzle.
Remove the parts as shown*. Clean all parts with a cleaning brush and the
appropriate cleaning solution.
Reassemble all parts when clean**.
4. Clean the air vent (c) on the suction tube with a soft bristled cleaning brush.
5. Push the tab below the trigger, twist and separate the nozzle from the
handle.
Clean the rear of the nozzle (b) with the appropriate cleaning solution. Use a
thin layer of petroleum jelly to lubricate the O-ring (c).
6. Reattach the handle to the nozzle.