Remove the adjustment ring (g. 29, 1)
carefully from the union nut (2).
Unscrew the union nut (g. 29, 2) and
remove the air cap (3), air screen (4) and
nozzle (5).
i
Never clean seals, diaphragm and
nozzle or air holes of the spray gun
with metal objects.
Do not immerse in solvent, only wipe.
Clean the air cap, air screen, nozzle seal, and
nozzle with a brush and water.
Assemble the parts again (see Assembly”).
Assembly
Attention! Never operate the
device if the nozzle seal (g. 30,
6) is either damaged or missing.
If the nozzle seal is either missing
or damaged liquids can enter the
device and increase the risk of an
electric shock.
Check the nozzle seal (g. 30, 6) in the
nozzle.
Place the nozzle (g. 31, 5) on to the gun
body with the recess facing downwards.
Attention: Position of needle must be
congruent with the nozzle aperture. (Fig.
32)