Owner`s manual
Technical Bulletin 13
L610 SPECIES ADJUSTMENT
In our quest to continually upgrade our products and
services, it has come to our attention that some of the
lesser used species adjustment values (SG) stored in the
default list of L610 hand-meter are not the correct values.
If you use any of the following species in your operation,
please store the new values to ensure the greatest
accuracy of your hand-meter. Should the internal lithium
battery in the meter fail, or the meter is sent in for
service, you will have to re-enter the appropriate values.
Please place this bulletin in the back of your L610
manual.
Change SG:
From
To
Keruing
0.69
0.64
Mahogany, True
0.45
0.59
Pine, Parana
0.46
0.54
Primavere
0.40
0.45
SYP
0.55
0.51
Teak
0.55
0.59
(Revised 10/28/02)
This change can be performed by turning on the meter
and editing the species value by pressing:
Menu > up/down arrows to select Change Species >
Store> Select appropriate species with up/down arrows >
Store > press Menu until “Edit” is displayed > up/down to
select new SG value > Store to save.
Wagner Meters
Technical Services Department
500-61001-001 Rev. F Page 18 of 30