Operating instructions
GB
15
WallPerfect W 665
The units may only be used with a functional valve.
•
If paints rises in the ventilating
hose (Fig. 12 A, item 14) do not operate the unit further! Dismantle and clean the
ventilating hose, valve and diaphragm and replace the diaphragm if necessary.
Do not lay the spray gun.
•
The device is equipped with a thermal release which disconnects the device in case of
•
overheating. In this case, turn o the device, remove the plug and let the device cool
down for at least 1/2 hour. Eliminate the cause of heating, e.g. bent hose, soiled air lter,
slots for air intake covered.
With original WAGNER accessories and spare parts, you have the guarantee that all
safety regulations are fullled.
Technical Data
Max. viscosity: 3000 mPaS
Power source: 230 -240 V ~
Power consumption: 350 W
Atomizing output: 105 W
Max. delivery rate 250 g/min
Double insulation:
Sound pressure level: 80 dB (A)
Oscillation level: < 2,5 m/s²
Air hose length: 3,5 m
Weight: 4,0 kg
Description (Fig. 1)
1 Air cup 10 Carrying belt
2 Nozzle 11 Air lter
3 Union nut 12 Air screen
4 Gun body WallPerfect spray
attachment
13 Mains lead
5 Trigger guard 14 Spray gun holder
6 Material volume regulation 15 Container
7 Handle 16 Ventilating hose
8 ON/OFF switch 17 Valve
9 Air hose 18 Feed hopper
Field of application
WallPerfect W 665 has been specially developed for the application of interior wall
paints.
Special spray attachments are required to process low-viscosity materials such as
paints, glazes etc.. These can be found under "Accessories".
Coating Materials Suitable for Use
Interior wall paint (dispersions and latex paint)
Coating Materials Not Suitable for Use
Materials that contain highly abrasive components, facade paint, caustic solutions and