Product Manual
Table Of Contents
- Table of Contents
- 1 Provisions
- 2 Safety
- 3 Overview
- 4 Properties
- 5 Functions
- 6 Planning
- 7 Transport and Storage
- 8 Installation and Removal
- 9 Connection
- 10 Commissioning
- 10.1 Setting an IP Address
- 10.2 Parameterization
- 10.2.1 PROFINET
- 10.2.2 WAGO Webserver I/O Field
- 10.2.2.1 Opening WAGO Webserver I/O Field
- 10.2.2.2 WAGO Webserver I/O Field User Interface
- 10.2.2.3 Opening the Product Information via WAGO Webserver I/O Field
- 10.2.2.3.1 Displaying Port Information
- 10.2.2.3.2 Displaying Measured Values and Information on Connected IO-Link Devices
- 10.2.2.3.3 Displaying Port Status Information
- 10.2.2.3.4 State
- 10.2.2.3.5 Quality
- 10.2.2.3.6 Revision ID
- 10.2.2.3.7 Baud Rate
- 10.2.2.3.8 Cycle Time
- 10.2.2.3.9 Input Data Length
- 10.2.2.3.10 Output Data Length
- 10.2.2.3.11 Vendor ID
- 10.2.2.3.12 Device ID
- 10.2.2.3.13 Displaying Process Data
- 10.2.2.4 Parameterizing the Product via WAGO Webserver I/O Field
- 10.2.2.4.1 Accessing a Connected IO-Link Device
- 10.2.2.4.2 Configuring Ports
- 10.2.2.4.3 Configuring IP Parameters
- 10.2.2.4.4 Storing Maintenance Information
- 10.2.2.4.5 Updating Firmware
- 10.2.2.4.6 Resetsetting the Module to the Factory Settings
- 10.2.2.4.7 Configure Bluetooth
- 10.2.2.4.8 Logging Users on and off and Managing Them
- 10.2.2.4.9 Forcing Digital Inputs and Outputs
- 10.2.2.4.10 Forcing IO-Link ports
- 10.2.3 WAGO IO-Link Configurator
- 10.2.3.1 System Requirements
- 10.2.3.2 Launching WAGO IO-Link Configurator
- 10.2.3.3 WAGO IO-Link Configurator User Interface
- 10.2.3.4 Parameterizing the Product with WAGO IO-Link Configurator
- 10.2.4 WAGO I/O Field app
- 10.2.5 OPC UA Server
- 11 Diagnostics
- 12 Service
- 13 Decommissioning
- 14 Appendix
- List of Tables
- List of Figures
765-4102/0100-0000 Safety
Product manual | Version: 2.1.0 11
8PORT IOL-B FLD PN DC 24V 2.0A
2Safety
This section contains safety rules that must be followed for hazard-free use of the prod-
uct.
This section is aimed at the following target groups:
• Planners and installers
• Operators
• Qualified assembly personnel
• Qualified installation personnel (electrical installation, technician network installation
etc.)
• Qualified operating personnel
• Qualified service and maintenance personnel
Obey the following safety rules:
2.1 General Safety Rules
• This documentation is part of the product. Therefore, retain the documentation during
the entire service life of the product. Pass on the documentation to any subsequent
user of the product. In addition, ensure that any supplement to this documentation is
included, if necessary.
• The product must only be installed and put into operation by qualified electrical special-
ists per EN 50110‑1/-2 and IEC 60364.
• Comply with the laws, standards, guidelines, local regulations and accepted technol-
ogy standards and practices applicable at the time of installation.
2.2 Electrical Safety
Power Supply
• Only operate the product with PELV or SELV power sources.
• Connecting impermissible current or frequency values may destroy the product.
Grounding/Protection/Fuses
• Connect the product and system to functional ground (FE).
• When handling the product, please ensure that environmental factors (personnel, work
space and packaging) are properly equalized. Do not touch any conducting parts.
Cables
• Maintain spacing between control, signal and data lines and the power supply lines.
Make sure the pin assignment is correct.
• Only use conductor cross-sections sufficient for the current load.
Protection
• When working on the system (e.g., during maintenance), protect the Facility part con-
cerned from accidental or unauthorized restart.