Product Manual
Table Of Contents
- Table of Contents
- 1 Provisions
- 2 Safety
- 3 Overview
- 4 Properties
- 5 Functions
- 6 Planning
- 7 Transport and Storage
- 8 Installation and Removal
- 9 Connection
- 10 Commissioning
- 10.1 Setting an IP Address
- 10.2 Parameterization
- 10.2.1 PROFINET
- 10.2.2 WAGO Webserver I/O Field
- 10.2.2.1 Opening WAGO Webserver I/O Field
- 10.2.2.2 WAGO Webserver I/O Field User Interface
- 10.2.2.3 Opening the Product Information via WAGO Webserver I/O Field
- 10.2.2.3.1 Displaying Port Information
- 10.2.2.3.2 Displaying Measured Values and Information on Connected IO-Link Devices
- 10.2.2.3.3 Displaying Port Status Information
- 10.2.2.3.4 State
- 10.2.2.3.5 Quality
- 10.2.2.3.6 Revision ID
- 10.2.2.3.7 Baud Rate
- 10.2.2.3.8 Cycle Time
- 10.2.2.3.9 Input Data Length
- 10.2.2.3.10 Output Data Length
- 10.2.2.3.11 Vendor ID
- 10.2.2.3.12 Device ID
- 10.2.2.3.13 Displaying Process Data
- 10.2.2.4 Parameterizing the Product via WAGO Webserver I/O Field
- 10.2.2.4.1 Accessing a Connected IO-Link Device
- 10.2.2.4.2 Configuring Ports
- 10.2.2.4.3 Configuring IP Parameters
- 10.2.2.4.4 Storing Maintenance Information
- 10.2.2.4.5 Updating Firmware
- 10.2.2.4.6 Resetsetting the Module to the Factory Settings
- 10.2.2.4.7 Configure Bluetooth
- 10.2.2.4.8 Logging Users on and off and Managing Them
- 10.2.2.4.9 Forcing Digital Inputs and Outputs
- 10.2.2.4.10 Forcing IO-Link ports
- 10.2.3 WAGO IO-Link Configurator
- 10.2.3.1 System Requirements
- 10.2.3.2 Launching WAGO IO-Link Configurator
- 10.2.3.3 WAGO IO-Link Configurator User Interface
- 10.2.3.4 Parameterizing the Product with WAGO IO-Link Configurator
- 10.2.4 WAGO I/O Field app
- 10.2.5 OPC UA Server
- 11 Diagnostics
- 12 Service
- 13 Decommissioning
- 14 Appendix
- List of Tables
- List of Figures
765-4102/0100-0000Commissioning
74 Product manual | Version: 2.1.0
8PORT IOL-B FLD PN DC 24V 2.0A
Table 45: Cycle Time of the Master
Bits 6...7 Calculation Formula
1 6.4ms + multiplier * 0.4ms
2 32.0ms + multiplier * 1.6ms
3 Reserved
10.2.2.3.9 Input Data Length
This shows the actual input data length of the connected product in bytes.
10.2.2.3.10 Output Data Length
This shows the actual output data length of the connected product in bytes.
10.2.2.3.11 Vendor ID
This value is the manufacturer ID of the connected product.
10.2.2.3.12 Device ID
This value is the device ID of the connected product.
10.2.2.3.13 Displaying Process Data
You can view the process data associated with a specific port on the Process Data tab.
Proceed as follows to view the process data for a port:
1. From the main menu of the Webserver (left), select the menu item which you want to
view information about.
2. Open the Process Data tab.
ð The Process Data tab opens. The current values of the process data configured for
input/output appear in hexadecimal format under Input/Output. If no process data has
been configured for a data direction (input or output), the corresponding field remains
empty.