Users Manual

765-1104/0100-0000Functions
28 Product manual | Version: 2.1.0
16DO FLD PN DC 24V 2.0A
User setup and management, as well as user login and logout
Reset product to factory settings and restart firmware
Simulating inputs; forcing outputs
Examples of port information include:
Display current measured values of the digital inputs and outputs: temperature, volt-
age, current and status on pins 1, 2 and 4
Display the status information for the entire port
Configure ports, e.g. set operating mode
Show process data
Examples of product settings include:
Select method for obtaining IP address
Select the origin of the configuration data used
Display and enter maintenance information
Reset product to factory settings
Load firmware onto the module
Display and set parameters for Bluetooth
®
connection to the module
Update Bluetooth
®
firmware
Function overview
The following overview shows the functions offered by WAGO Webserver I/O Field that is
integrated into the product and the menu items/tabs in the user interface that can be used
to address these functions:
Table 24: Function Overview for WAGO Webserver I/O Field for Digital Input/Output Modules
Menu Tab Description Section
Dashboard - Displaying product infor-
mation
Ports X01, X02 etc. (All) Port information and set-
tings for the IO-Link ports
X01, X02, ...
8Configure Ports
[}62]
Information Display current measured
values for the port (tem-
perature, voltage, current
and status on pins1, 2
and 4) and information on
the connected IO-Link de-
vice
Status Displays status information
for the entire port
Configuration Make port settings (such
as operating mode or
product check for valida-
tion and backup)
IOL Access to connected IO-
Link device
Process data Display process data (in-
put/output)