Data Sheet

Data sheet | Item number:289-454
www.wago.com/289-454
06.12.2018Page /2 4
Data
Electrical data
Operating voltage ≤ 30 VAC; ≤ 50 VDC
Nominal current 1 A
Contact resistance (max.) 30 mΩ
Safety and protection:
Rated voltage 50 V
Rated impulse voltage 0.8 kV
Pollution degree 2
Degree of protection IP00*
Note on Protection Type * Notice!Live conductors! Protection against direct contact must be
provided by the equipment builder, e.g., using a WAGO 709 Series
cover (see Accessories) or a similar cover. The installation
requirements for the particular application must be observed.
Connection data
No. of poles 50
Connection type (1) System
No. of poles 50