User Manual

40 Properties Touch Panel Standard Line
762-4xxx TP 600
Manual
Version 1.3.0
4.4.9 “X8” Line-out Audio Output (Headphones)
(Only with PIO2 and PIO3 Hardware)
The audio output is a three-pole, 3.5 mm stereo socket. Headphones or a
compatible audio device can be connected to this socket, e.g. in order to output
acoustic warning signals or voice messages that the control application contains.
4.4.10 “X11” Four Digital Inputs and Outputs DIO
(Only with PIO3 Hardware)
There are four digital connectors, configurable as inputs or outputs, for
connecting actuators and sensors.
A 10-pole picoMAX
®
plug is used with 10 push-in CAGE CLAMP®S connections
(female connector 2091-1110).
Table 14: X11 Pin Assignment
CAGE CLAMP
®
Name
Assignment
1
GND
Reference potential 0 V (ground)
2
DIO 0
Digital I/O 0
3
GND
Reference potential 0 V (ground)
4
DIO 1
Digital I/O 1
5
GND
Reference potential 0 V (ground)
6
DIO 2
Digital I/O 2
7
GND
Reference potential 0 V (ground)
8
DIO 3
Digital I/O 3
9
GND
Reference potential 0 V (ground)
10
24VDC
Supply voltage for digital inputs and outputs
The digital inputs/outputs are electrically isolated from the supply voltage of the
panel and from the other interfaces.