User Manual

136 Commissioning Touch Panel Standard Line
762-4xxx TP 600
Manual
Version 1.3.0
Table 106: WBM “Configuration of Cloud Connectivity” Page “Settings” Group
Parameter
Explanation
Key file
Enter the path here to the file encoded in PEM
format that contains the private key for cloud service
authentication.
Use websockets
Here, you can specify whether the connection to the
cloud platform is to be set up using the Websocket
protocol via Port 443.
If this box is not checked, the connection to the
cloud platform will be set up using the MQTT
protocol via Port 8883.
Use compression
Here, you can set whether the data is to be
compressed using GZIP compression.
Data Protocol
Here you can select the data protocol.
Cache mode
Specify here in which memory the cache for the data
telegrams should be created.
This selection field is only enabled if a correctly
formatted SD card is inserted.
(You can find more information in Application Note
A500920.)
Last Will
Here you can specify whether a last will message
should be enabled/disabled.
(Last Will) Topic
Here you can specify the topic under which the last
will messages should be sent.
(Last Will) Message
Here you can enter the message you wish to use as
the last will message.
(Last Will) QoS
Here you can specify the “Quality of Service” (QoS)
of the last will message.
(Last Will) Retain
Here, you can set whether the previous last-will
message sent under a topic from the broker is to be
handled as a retained message.
Device info
Specify here whether a device info message should
be generated that informs the cloud service of the
basic configuration of the PFC.
(You can find more information in Application Note
A500920.)
Device status
Specify here whether device state messages should
be generated that inform the cloud service about
changes in the mode selector switch and the LEDs.
(You can find more information in Application Note
A500920.)
Standard commands
Specify here whether the integrated standard
commands should be supported.
(You can find the list of standard commands in
Application Note A500920.)
If the check box is disabled, only the commands