User Manual

34 Properties Touch Panel Marine Line
762-6xxx/8000-000x TP 600
Manual
Version 1.1.0
Continuous shielding is essential in order to increase the immunity to
interference. For this purpose, the metallic housing of the socket is connected to
functional ground.
The connected data cable must be shielded. The cable clamp that is used must
guarantee sufficient strain relief and contact between the shield and housing over
a large area at the same time.
4.4.5 “X4” CAN Interface
(Only with PIO3 Hardware)
This interface is designed as a D-sub 9 plug and is electrically isolated from the
supply voltage of the device and the other interfaces.
The interface corresponds to ISO 11898-2.
Table 1: X4 Pin Assignment
Pin
Assignment
1
-
2
CAN-L (CAN data low)
3
GND (reference potential 0 V or ground)
4
-
5
-
6
-
7
CAN-H (CAN data high)
8
-
9
-
Continuous shielding is essential in order to increase the immunity to
interference. The metallic housing of the plug is capacitively connected to
functional ground.
The connected data cable must be shielded. The cable clamp that is used must
guarantee sufficient strain relief and contact between the shield and housing over
a large area at the same time.
4.4.6 “X5” Supply Voltage
Connect the supply voltage to the X5 connector. For this, use the included 734-
103 female connector featuring three CAGE CLAMP
®
connections.
For more information about the supply voltage, see section “Device Description”
> “Technical Data”.