Data Sheet

Data sheet | Item number:859-314
www.wago.com/859-314
06.12.2018Page /2 9
Data
Technical Data
Control circuit
Nominal input voltage U
N
24 VDC
Input voltage range -15 … +20 %
Nominal input current at U
N
10 mA
Load circuit:
Number of changeover/switchover contacts 1
Contact material (relay) AgNi + Au
Limiting continuous current 5 A
Max. switching voltage 250 VAC
Max. switching power (resistive) 1250 VAAC; DC see load limit curve
Recommended minimum load 1 V / 1 mA / 1 mW
Pull-in time (typ.) 8 ms
Drop-out time (typ.) 4 ms
Bounce time (typ) 5 ms
Electrical life (N.O.; resistive load; 23 °C)
50 x 10 switching operations
3
Mechanical life (N.O.; resistive load; 23 °C)
5 x 10 switching operations
6
Max. switching load with load/without load
6 min / 180 min
-1 -1
Signaling
Status indication LED red
Safety and protection:
Rated voltage 250 V
Rated impulse voltage 4 kV
Pollution degree 2
Dielectric strength, control/load circuit (AC, 1 min) 4 kV
rms
Dielectric strength, control/load circuit (AC, 1 min) 4 kV
rms
Dielectric strength open contact (AC, 1 min) 1 kV
rms
Dielectric strength open contact (AC, 1 min) 1 kV
rms
Connection data
Connection technology
CAGE CLAMP
®
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG