Specifications

4
Complete Calibration Services Available
Wahl
®
DST600
01/09
173 Y
ears of Continued Innovation
ISO9001:2000 CERTIFIED
(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com
Calibration and Programming
Software and Accessories
Meter Calibration of a Digi-Stem Meter
utilizing a decade box and USB to Computer Inter
face Box.
DST600 Fixed Probe Calibration Cable Assembly - 13500-03
Extends the probe leads when performing system calibrations on
fixed probe systems. Allows the meter to be conveniently placed
on the benchtop, while the probe is installed in an ice bath.
DST600 Interconnect Calibration Cable - When probe wiring is
difficult to remove, simply disconnect the probe and meter from
the cable, and use the 2 meter interconnect cable for performing
lab calibration. Determine appropriate model number below,
based on length of installed cable.
System Calibration of a Remote Digi-Stem utilizing an ice bath and
USB to Computer Interface Box
Software Accessories
Ice Bath
Decade Box
WARRANTY
Wahl DSTPROG and DSTCAL Software Kits are user
friendly and include on-screen prompts for guiding the
user through their operation. Both Kits require Windows
XP to operate,
and include a
USB cable,
USB to
Computer
Interface Box,
and Digi-Stem
Serial Interface
Cable in order
to connect the
Wahl DST600
to a PC.
DSTCAL Calibration Software Kit - This exclusive software
allows setting of the same configuration parameters as
DSTPROG, but also allows the following calibrations:
Meter Calibration - uses an ohmmeter to calibrate the
resistance measurement electronics by connecting to
known fixed resistances.
System Calibration - used to calibrate a sensor to a meter
using a standard ice bath.
DST600 Calibration Software
DST600 Programming Software
DSTPROG Programming Software Kit - This software allows
the customer to configure the following parameters:
Sample/Display Rate - Factory default at 1/second.
Adjustable from .25 seconds to 10 seconds in .25 second
intervals. Slower update rates extend battery life.
Probe R0 - Compensation feature which allows calibration
of meter to be “matched” to probe.
Probe Authorization - Allows user to change probes and
authorize a new probe with the existing meter.
Probe ID - The unique Probe ID feature verifies that the author-
ized probe is connected to the meter. If an unauthorized probe is
connected, the meter will display “
Prb”, indicating the need to
perform the probe authorization and probe calibration functions.
Probe ID is available on Adjustable Angle, Rigid, and Remote
probes up to 30-meter lengths.
NO OTHER SYSTEM HAS THIS SAFETY FEATURE!
Probe R0 - The Wahl DST600 includes an exclusive compensa-
tion feature utilizing a programmable R0 calibration coefficient
for increased accuracy. This allows the meter and probe to be
“matched” to each other, and along with the Probe ID feature,
guarantees an accurate and secure system.
Probe ID and Probe Rø
W
ahl USB to Computer
Inter
face Box, USB Cable, and
Digi-Stem Serial Interface Cable
12370-002 - 2 meter length, 6 conductor cable for use in
calibration when installed r
emote cable cannot be easily
removed.