Installation and Operation Manual Gas Salamander SN8200G SN8200GB Date Purchased Serial Number Dealer Service Provider 232460-6
MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: E.Mail: Main Office: Service: Spares: Customer Service: www.moffat.com.au vsales@moffat.com.au (tel) +61 (03) 9518 3888 (fax) +61 (03) 9518 3833 (tel): 1800 622 216 (tel): 1800 337 963 (tel): 1800 335 315 (fax): 1800 350 281 CANADA Serve Canada Web: E.Mail: Sales: Service: www.servecanada.com info@servecanada.
Contents SN8200G GAS SALAMANDER (Branding Plate Optional) SN8200GB GAS SALAMANDER (With Branding Plate) Introduction .............................................................................................. 2 Specifications ............................................................................................ 3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions ..................................................................................
Introduction We are confident that you will be delighted with your Waldorf Gas Salamander, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf Gas Salamander, there are two important things you can do. Firstly: Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Specifications Model Numbers Covered in this Specification SN8200G Gas Salamander. SN8200GB Gas Salamander. General A commercial heavy duty, wall mounted gas fired infra-red grilling Salamander for a wide range of foods. Blue Seal Salamanders feature independently controlled heat zones for left and right side of cooking area. Two high speed infrared surface combustion burners in ceiling of cavity are independently operated with left and right hand side controls of the appliance.
Dimensions Dimensions: 900 401 424 32 GAS ENTRY 128 25 Side Front Plan Internal Dimensions Width 685mm. Height 230mm (at front). Depth 330mm. Cooking Area Rack 610mm x 310mm. Branding Plate (Accessory) 610mm x 310mm. Weight (Nett) 41kg (without Branding Plate or Racking System).
Installation Installation Requirements NOTE: It is most important that this salamander is installed correctly and that operation is correct before use. Installation shall comply with local gas, health and safety requirements. Waldorf Salamanders are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
Installation If appliance is not mounted under an extraction hood, installer must ensure that all regulations are met and that there is an unobstructed minimum distance of 750mm from top surface of appliance to ceiling, which must be of non-combustible material. NOTE: Do not obstruct or block appliance flue. Never directly connect a ventilation system to appliance flue outlet. Clearances NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Installation Wall Mounting (To Non-Combustible Wall Only) 1. Fix wall mounting bracket to wall with six screws, in a position where top of bracket is level and at least 945mm (38”) above any surface beneath unit. This will ensure that bottom of Salamander is at least 600mm (24”) above any surface. 2. Fit two black plastic spacers to top rear of unit. Leave them unscrewed by approximately 5mm. 3. ~ 5mm Fit two adjusting screws / bolts into nutserts at bottom rear corners of unit.
Installation Gas Connection NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON. 1. 2. Waldorf Salamanders do not require an electrical connection, as they function totally on gas supply only. It is essential that gas supply is correct for Salamander to be installed and that adequate supply pressure and volume are available. The following checks should be made before installation:a.
Installation Commissioning 1. Before leaving the new installation; a. Check the following functions in accordance with operating instructions specified in Operation section of this manual. Light the Main Burners. Check the Low Fire burner operation. Check the High Fire burner operation. Check the Racking System operation. b. Ensure that operator has been instructed in areas of correct lighting, operation, and shutdown procedure for appliance. 2.
Operation Operation Guide Caution This appliance is for professional use and is only to be used by qualified persons. Only authorised service persons are to carry out installation, servicing or gas conversion operations. Components having adjustments protected (e.g. paint sealed) manufacturer should not be adjusted by the user / operator. 1. 2. by the Waldorf Salamanders have been designed to provide simplicity of operation and 100% safety protection.
Operation Lighting Main Burners 1. 2. 3. 4. 5. 6. Check that gas supply is turned 'On'. Depress gas control knob and rotate anti-clockwise to 'HIGH' position. With gas control knob depressed, press piezo ignition button to ignite main burner. Once lit main burner will be burning at full rate. For a lower heat, depress gas control knob and turn fully anti-clockwise to 'LOW' position. For intermediate heat, position control knob between 'HIGH' and 'LOW' positions.
Cleaning and Maintenance General Caution Always turn ‘Off’ gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. To achieve the best results, cleaning must be thorough, and all controls and mechanical parts checked and adjusted periodically by a competent serviceman. If any small faults occur, have them attended to promptly. Don't wait until they cause a complete breakdown.
Cleaning and Maintenance Periodic Maintenance NOTE: All maintenance operations should only be carried out by a qualified service person. To achieve the best results, cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service person. If any small faults occur, have them attended to promptly. Don't wait until they cause a complete breakdown. It is recommended that the appliance is serviced every 6 months.
Fault Finding This section provides an easy reference guide to the more common problems that may occur during operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure Caution Ensure Appliance is isolated from gas supply before commencing servicing. NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. For all the following conversion instructions, the side access panels have to be removed (Remove two screws at bottom of each side panel). All conversion details apply to both L/Hand and R/Hand burners.
Gas Conversion and Specifications Gas Regulators NOTE, Pin rotated for Natural Gas NAT Gas / LPG / Butane Only. NOTE: The gas regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex-factory and is NOT to be adjusted. NOTE, Pin rotated for LPG Cap Nut - Town Gas Only. 1. 2. 3. Remove slotted cap from regulator. Turn ‘On’ gas supply and appliance. Adjust pressure adjusting screw to achieve correct burner operating pressure.
Gas Conversion and Specifications Gas Specifications Main Burner Injectors Low Fire: Size Adjustment Supply Pressure Operating Pressure Natural Gas LP Gas Butane Gas Ø 1.85mm Ø 1.15mm Ø 1.10mm Town Gas Conversion Ø 3.50mm Ø 1.00mm Ø 1.00mm Ø 1.00mm 2 turns out (ccw) ½ turn out (ccw) 4 turns out (ccw) 1.13 - 3.40 kPa 2.75 - 4.50 kPa 0.76 - 1.50 kPa 1.00 kPa (*) 2.55 kPa (*) 0.
Replacement Parts List Replacement Parts List When ordering spare parts, please quote part number and description as listed below. If part required is not listed below, request part by description and quote model number and serial number which is shown on rating plate. Controls 019430 227967 Gas Control Valve. Control Knob (No Pilot). 034185 034115 034110 032350 Main Main Main Main 019574 019214K 026123 232067 231536 227508 Low Fire Screw (Nat. Gas / LPG / Town Gas) Burner Kit. Burner Guard.