MODEL: STAR COLPOSCOPE USER’S MANUAL ZOOMSTAR™ with TRULIGHT™ COLPOSCOPE TRISTAR™ with TRULIGHT™ COLPOSCOPE REF: 906057T, 906057-40TU, 906140T WALLACH® SURGICAL DEVICES 95 Corporate Drive Trumbull, CT 06611 USA Phone: (203) 799-2000 Fax: (203) 799-2002 www,wallachsurgical.com EC REP EMERGO EUROPE Molenstraat 15 2513 BH, The Hague The Netherlands IMSC036-DFU • Rev.
Table of Contents Cautions .......................................................................................................... 3 ZoomStar™ Assembly Instructions........................................................................... 4 Operating Instructions .......................................................................... 4 Illumination ........................................................................................... 5 Focusing Instructions ......................................
Read all safety information and instructions before using this product! CAUTIONS: DO NOT USE IN THE PRESENCE OF FLAMMABLE ANESTHETICS. OBSERVE PRECAUTIONS FOR ELECTROSTATIC DISCHARGE (ESD) AND ELECTROMAGNETIC INTERFERENCE (EMI) TO AND FROM OTHER EQUIPMENT. LED RADIATION; DO NOT STARE DIRECTLY INTO BEAM. DO NOT OPERATE PRODUCT IF IT APPEARS TO HAVE BEEN DROPPED OR DAMAGED. REMOVE AC POWER FROM ZOOMSTAR BEFORE CHECKING FOR A BLOWN FUSE.
ASSEMBLY INSTRUCTIONS The ZoomStar™ with Trulight™ colposcope has three parts. The Optics with eyepieces Center Pole with the power control box The Floor stand 1. Place the floor stand on the floor. 2. Insert the tapered end of the shaft on the bottom of the center pole into the center hole of the floor stand. Attach the center pole to the floor stand using the tools and hardware supplied with the floor stand. 3. Place the microscope head into the retaining ring with ocular tubes pointed upwards.
7. To lock the head tilt angle, tighten the head pitch knob snugly, but do not over tighten. Loosen the knob to release angle position. 8. For transportation of the colposcope, place the colposcope head in the lowest position to assure stability during transportation. ILLUMINATION a. LED Light Frequency b. Dominant Wave Length for Green Light Emitting Diode Minimum value 530 nm (nanometers) Maximum value 535 nm (nanometers) FOCUSING INSTRUCTIONS 1.
ZOOMSTAR WITH TRULIGHT, USB VIDEO Sentech USB Camera Setup 1. Install Sentech Image Viewing Software (StCamSWare) onto laptop desktop. (see Quick Start Guide IMSC031) 2. Attach Video ZoomStar microscope head to laptop via USB cable provided. 3. Turn on Colposcope. 4. Double click on the “STCamSWare” icon on the desktop. 5. Using the cursor, choose “Options,” then “Settings”. A window will open at the bottom right of screen. 6. Check the “Auto” boxes next to the Gain and Shutter features. 7.
TriStar™ The TriStar™ with Trulight™ Colposcope is a highly versatile triple magnification stereoscopic colposcope. A magnification of 8x, 13x and 21x is obtained with the 3-step magnification changer. The field of view diameters are 24mm, 15mm and 9mm. A vessel delineation filter is incorporated to provide clear visualization of vascular patterns.
FOCUSING THE TRISTAR 1. Set the binocular eyepieces to “0” and adjust them to the proper interpupillary distance. 2. Peering through the eyepieces, move the entire TriStar backwards or forwards to get a “rough” focus on the target. (12” or 300mm from objective lens to target.) 3. Set the fine focus by rotating the fine focus adjust lever (the same lever as the tilt adjust) until the rack is at the midpoint. 4. Focus at the highest magnification.
USB Video Attachment There is a video camera C-Mount Adaptor available to attach any analog or USB camera. (Please note that only one side of the C-Mount Adaptor can attach to the TriStar.) The instructions are as follows: 1. Attach the mounting ring to the camera. 2. Attach the entire camera to the C-mount Adaptor. IMSC036-DFU • Rev.
3. Then attach the C-Mount Adaptor to the TriStar. 4. Plug in the S video cable if you have an analog camera. Next, plug in the power supply. Then plug the power supply into the wall. For a USB camera, plug the USB cable into the camera and the other end into the US port on the laptop or PC. 5. After the C Mount has been attached to the colposcope, the camera needs to be oriented so that the image on the monitor is the same as that viewed through the optical head.
Electrical The Wallach Colposcope with Trulight requires a 100-240V ~50-60 Hz power source to operate. It is supplied through a 2.5 meter medical grade detachable cord. For your safety, assure that your electrical outlets meet code regulations. Replacing the Fuses 1. Shut OFF (labeled “O”) the master switch and unplug the power cord. 2. The electronics box contains two fuses beneath the power socket. 3. To remove, pull out the drawer beneath the power socket. 4.
Service and Repair Only Wallach Surgical Devices is authorized to service or repair this unit. If repair is attempted outside the factory, the warranty will be considered void. Wallach Surgical Devices is not responsible for any injury resulting from repairs made by other individuals or organizations not certified by Wallach Surgical Devices. In the event your Colposcope with Trulight becomes inoperative, please make the following checks before calling the factory. 1.
Explanation of Symbols Reorder number Serial number Consult instructions for use Caution U.S. Federal law restricts this device to sale by or on the order of a physician. For professional use only Product conforms to the Medical Device Directive 93/42/EEC Authorized Representative in the European Community.
Specifications ZOOMSTAR™ SPECIFICATIONS Nikon Continuous Zoom Optics 4.5x to 20x Maximum height 51”; minimum height 40” Overall weight 23 ½ lbs. Center of column to end of leg 12” Height of microscope to floor 36” to 46” 8 ½ foot grounded power cord Fused power input lamp 2.
For All Star Colposcope Models CLASSIFICATION Model Star with Trulight Colposcopes Safety Class I ALL models of Colposcopes have no Applied Parts. Do not get fluid into the Colposcope. Should any liquid or solid object fall into the unit, unplug the unit and call Technical Support (866) 928-3211. The LED Model Colposcopes are suitable for continuous operation. The LED Model Colposcopes are classified as normal equipment (IPX0) according to protection against ingress of water.
Wallach Colposcopes EMC Compliance Information MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS. Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT. Guidance and Manufacturer’s Declaration – Electromagnetic Emissions The Wallach Colposcope is intended for use in the electromagnet environment specified below.
Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The Wallach Colposcopes are intended for use in the electromagnet environment specified below. The customer or the end user of the Wallach Colposcopes should assure that it is used in such an environment. Immunity Test Electromagnetic discharge (ESD) IEC 60601 Test Level Compliance Level Electromagnetic Environmental – Guidance +6 kV contact +6 kV contact +8 kV air +8 kV air Floors should be wood, concrete or ceramic tile.
Guidance and Manufacturer’s Declaration – Electromagnetic Immunity (continued) Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environmental Guidance Portable and mobile RF communications equipment should be used no closer to any part of the Wallach Colposcope, including cables , than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended Separation Distance This section discusses the Recommended Separation Distance between portable and mobile RF communications equipment and the Wallach Colposcopes. The Wallach Colposcopes are intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
SURGICAL DEVICES 95 Corporate Drive Trumbull, CT 06611 USA Phone: (203) 799-2000 Fax: (203) 799-2002 www.wallachsurgical.com IMSC036-DFU • Rev.