- Cable runs through air between buildings are less than 42m (140ft).
- Cable runs between buildings are directly buried.
- Cable runs between buildings are in underground conduit, where a continuous metallic
cable shield or a continuous metallic conduit containing the cable is bonded to each
building grounding electrode system.
*These options are from the US National Electrical Code, Sections 800.10, 800.12, 800.13, 800.31, 800.32,
800.33, and 800.40.
5.4 Installation Instructions
This device should be securely mounted to a fixed surface using either the 4 5.5mm
(.22”) diameter mounting holes located at the corners of the unit, OR the Quick Release
Adaptor Mount (PN-006028, Figure 5) in conjunction with the Sheet Metal Mount (PN:
310-003470, Figure 6). Mounting with the 4 holes in the corner provides the lowest
profile mounting option, while the Quick Release Adaptor Mount in conjunction with the
Sheet Metal Mount provides a convenient method of attaching the device while
providing the ability to quickly remove or replace the device.
Figure 4 - xBR V4 Module
When mounting the xBR V4 unit directly, the must be securely attached to the
mounting surface via the 4 mounting holes. For example, when mounting on drywall,
wall anchors, toggle bolts, or expansion anchors should be used to provide more secure
attachment points.