Operating Instructions and Installation Instructions

33
Type
TYP11180
TYP11181
TYP11182
TYP11183
TYP11186
TYP11187
TYP11189
TYP10180
TYP10181
TYP10182
TYP10183
TYP10186
TYP10187
TYP10189
TYP10886
Nominal performance 6 kW 8 kW
Heating capacity (m
3
)
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
116
69
47
182
105
71
Flue gas values: fuel:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
CO (relating to 13% O²)
dust (relating to 13% O²)
efficiency
wood / brown coal
6,2 / 7,2 g/s
268 / 271°C
12 Pa
40 mg/m³
1032 / 769 mg/Nm
3
82 / 79,7 %
wood / brown coal
7,9 / 8,6 g/s
295 / 316°C
12 Pa
40 mg/m³
1078 / 729 mg/Nm
3
80,3 / 78,6 %
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions