Operating Instructions and Installation Instructions
Table Of Contents
- Holztrocknung und -Lagerung
- 1.6 Störungsursachen, Behebung
- 3. Technische Daten
- Produktbezeichnung: Kaminofen
- 1.6 Potential problems and how to tackle them
- 3. Technical specification
- Préambule
- 1.6 Anomalies
- 3.3 Data
- 1.6 Cause e risoluzione anomalie
- 3.1 Disegni dimensionali e dati
- 3.2 Dimensioni
- 3.3 Dati
- 1.1 A kandalló felépítése
- 3.2 Méret adatok

31
3.2 Dimension
Art.No.
width
(mm)
draught
(mm)
height
(mm)
weight
netto
(kg)
W20001985400 396 439 874 63
W20001985405 396 439 874 63
W20001985410 396 441 874 63
The specified dimensions and weights are approximate values, and thus have only informative
purposes. We reserve the right to modify the designs as required in terms of technology or quality!
3.3 Datas
Type TYP198 54
Nominal performance 6,5 kW
Heating capacity (m
3
)
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
132
78
52
Flue gas values: fuel:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
CO (relating to 13% O²)
dust (relating to 13% O²)
efficiency
wood
6 g/s
300 ˚C
11 Pa
≤ 40 mg/m³
1567 mg/m³
≥ 76 %
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions