DANTA installation, servicing and user instructions 500 - 800 - 1100 - 1400 - Koto includes Front, Corner, Bay and Room Divider GB IE This appliance has been tested and certified for other counties (see technical data). However to install appliance in other countries, modification of the appliance and its method of installation may be necessary in order to use the appliance safely and correctly. The manual for the local language must be obtained. Contact Wanders for further information.
installation, servicing and user instructions manual | GB + IE 1. General Notes 2. User instructions 2.1 First Time of Operation 2.2 Remote Control Overview 2.3 Batteries 2.4 Replacing the batteries 2.5 Setting the Transmitter code 2.6 To Ignite the appliance 2.7 To Turn the appliance OFF 2.8 Adjusting the Flame setting 2.9 Using the "Effect" Burner 2.10 Setting °C/24 hour or °F/12 hour clock 2.11 Setting the Time 2.12 Cleaning and Maintenance 3. Installation instructions 3.1 Gas Connection 3.
1. General Notes This Wanders gas appliance is a High Efficiency, Balanced Flue Live Fuel Effect appliance. It provides radiant and convected heat using the latest burner technology. As well as having a variable heat output, these fires also utilise a special control system that allows the appliance to use two burners for high output or a single burner for lower outputs.
installation, servicing and user instructions manual | GB + IE 2. User instructions 2.1 First Time of Operation Before igniting the appliance, ensure that all packaging, safety stickers and any protective wrapping have been removed, and that the glass has been cleaned, including all fingerprints from the glass. Ensure that the room is adequately ventilated the first time that the appliance is ignited; we would recommend opening windows if possible.
2.3 Batteries Remote Handset: 1 x 9V "PP3" Battery, Quality alkaline recommended Receiver: 4 x 1.5V "AA", Quality alkaline recommended for maximum life. An alternative AC Mains Adaptor may be used to power the Receiver instead of the 4 AA batteries. Only an AC Mains Adapter supplied by Wanders may be used. The Mains Adaptor is plugged into the DC 6V socket on the end of the receiver.
installation, servicing and user instructions manual | GB + IE Note: - Repeated presses of the small flame (Button D fig. 1.1) will turn the main burner OFF, but will leave the Pilot alight. 2.8 Adjusting the Flame setting To increase the flame height; press the large flame button (Button C fig. 1.1). To decrease the flame height; press the small flame button (Button D fig. 1.1). 2.9 Using the "Effect" Burner Note: The solenoid valve will not operate for one minute after Ignition.
3. Installation instructions Before commencing Installation, confirm that the details on the appliance data plate correspond to the local distribution conditions, gas type and pressure to which the appliance is to be installed. Ensure that gas supply and supply pipe is capable of delivering the required volume and pressure of gas and is in accordance with the rules in force. 3.1 Gas Connection This appliance has a gas inlet connection of Ø 8mm. 3.
installation, servicing and user instructions manual | GB + IE 3.3.2 Built-In Fireplace Sizing (assuming a Cement Board Lining is used) D C B F A Free Vent Area 200 cm² E 250 175 Control Access Door Cut-out D C Detail Y Y Max.
Built in fireplace sizing Corner appliances D B C Free Vent Area 200 cm² E H G Appliance Danta 500 Front Danta 500 Bay Danta 500 Corner Danta 800 Front Danta 800 Bay Danta 800 Corner Danta 1100 Front Danta 1100 Bay Danta 1100 Corner Danta 1100 Front Danta 1100 Bay Danta 1100 Corner Koto 10 A min 515 n/a n/a 815 n/a n/a 1115 n/a n/a 1415 n/a n/a 1316 B min 375 375 375 375 375 375 375 375 375 375 375 375 395 C min 650 555 600 850 855 900 1150 1155 1200 1450 1455 1500 1500 D min 490 490 490 490 49
installation, servicing and user instructions manual | GB + IE 3.3.4 Mantel Clearances 3.3.4.
3.3.4.b Combustible Mantel/Side Wall – Top view A Fireplace Opening Cement Board Minimum Thickness 12mm Area denotes allowable location for combustible mantel 25 (1") 50 (2") 75 (3") Fireplace Opening 50 (2") 75 (3") 100 (4") 125 (5") Wall Min.
installation, servicing and user instructions manual | GB + IE 3.4 Flue Connection 3.4.1 General notes This appliance may be installed with a roof terminal (C31) or a wall terminal (C11). This appliance may only be used with Balanced Flue (otherwise known as Concentric Flue) parts as specified by Wanders. The Wanders specified flue parts have been approved with the appliance.
3.4.5 Terminal Locations Dimension Terminal Position Distance (mm) A* Directly below an opening, air brick, opening window etc. 600 B Above an opening, air brick, opening window etc. 300 C Adjacent to an opening, air brick, opening window etc.
installation, servicing and user instructions manual | GB + IE 3.4.6 Horizontal Wall Vent Termination type C11 Flue sizing: Danta 500: Ø100/150 Connector on Appliance. Ø100/150 to be used Throughout. Flue Terminal: Ø100/150 Part No. INK.4330 Danta 800, 1100, 1400 & Koto: Flue Terminal: Vertical Flue Rise (V) in metres 0,5 1 1,5 2 2,5 3 3,5 4 4,5 Ø130/200 Connector on Appliance. Ø130/200 to be used Throughout. Ø130/200 Part No. INK.
3.4.7 Vertical Roof Vent Termination C31 Flue sizing: Danta 500: Ø100/150 Connector on Appliance,Ø100/150 to be used Throughout. Flue Terminal: Ø100/150 Part No. INK.4335 Danta 800, 1100, 1400 & Koto: Ø130/200 Connector on Appliance,Ø130/200 to be used Throughout. Flue Terminal: Ø130/200 Part No. n/a Minimum Vertical Flue Height: 0.5m Vertical Rise (m) 11 (Max.
installation, servicing and user instructions manual | GB + IE Vertical Rise (m) 11 (Max.) 10 7-11m 60mm RESTRICTOR MAXIMUM VERTICAL FLUE FOR DANTA 800 AND FLUE RESTRICTOR SELECTION 9 200/130 SPIGOT ON APPLIANCE 200/130 - 150/100 REDUCER ONTO SPIGOT, 150/100 FLUE USED THERE AFTER.
Vertical Rise (m) 11 (Max.) 10 MAXIMUM VERTICAL FLUE FOR DANTA 1100 (& KOTO) AND FLUE RESTRICTOR SELECTION 8-11m 60mm RESTRICTOR 9 8 200/130 SPIGOT ON APPLIANCE 200/130 - 150/100 REDUCER ONTO SPIGOT, 150/100 FLUE USED THERE AFTER.
installation, servicing and user instructions manual | GB + IE Vertical Rise (m) 11 (Max.) 10 7-11m 60mm RESTRICTOR MAXIMUM VERTICAL FLUE FOR DANTA 1400 AND FLUE RESTRICTOR SELECTION 9 200/130 SPIGOT ON APPLIANCE 200/130 FLUE USED FOR 1st METRE (Min), THEN 200/130 - 150/100 REDUCER 150/100 FLUE USED THERE AFTER.
3.4.
installation, servicing and user instructions manual | GB + IE 3.5 Fuel Bed Media and Arrangements When arranging the Media in the Fire, it is always important to keep the Pilot area clear and ensure smooth cross lighting from the Pilot to the Main Burner and of the Effect burner from the Main burner.
3.5.1 Danta 500 Used logs: B - D - D - G 3.5.
installation, servicing and user instructions manual | GB + IE 3.5.
3.5.
installation, servicing and user instructions manual | GB + IE 3.5.5 Pebbles • Scatter the bag of Pebbles over the top of the Burners and Grate, making sure that the Pilot area is left clear. • Ensure smooth cross lighting of the Burners. 3.5.6 Stones • Scatter the bag of Stones over the top of the Burners and Grate, making sure that the Pilot area is left clear. • Ensure smooth cross lighting of the Burners.
3.5.7 Graphite • Scatter the bag of Graphite over the top of the Burners and Grate, making sure that the Pilot area is left clear. • Ensure smooth cross lighting of the Burners. 3.6 Commissioning the Appliance 3.6.1 Pilot Ignition Check 1. Ignite the pilot light as described in the User Instructions 2. Check that the pilot flame stays alight 3. Extinguish the pilot light 3.6.2 Main Burner Check 1. Ignite the pilot light as described in the User Instructions 2.
installation, servicing and user instructions manual | GB + IE 4. Servicing Turn the appliance OFF and isolate the gas supply. Ensure the appliance is fully cold before attempting to start servicing the appliance. No liability can be accepted by Wanders for injury caused by burning or scolding by a hot appliance. A suggested procedure for servicing is listed below. A. Lay out dust sheet on flooring, mask off any special fireplace materials. B. Remove Side Window Trims C. Remove Bottom Window Trim D.
4.3 Spare parts Part description Partnumber for Danta 500 Partnumber for Danta 800 Glass (front) Glass (side) Glass (back) Log set Remote handset Remote receiver Adapter Thermocouple Rope (glass - body) Rope (glassclips) Spraycan (400 ml) GLA.00.0770 GLA.00.0750 GLA.00.0720 GLA.00.0700 GLA.00.0730 GLA.00.0760 GLA.00.0740 GLA.00.0710 INK.00.6031 INK.00.6032 INK.00.6033 INK.3252 INK.3253 INK.3270 Mertik selfadhesive 15 x 3 selfadhesive 10 x 3 INK.8001 GLA.00.0780 INK.00.
installation, servicing and user instructions manual | GB + IE 5. Technical Information 5.
5.2 Technical Data Product Identification Number: • 0359CO1364 for Danta, • 0359CP1411 for Koto 5.2.
installation, servicing and user instructions manual | GB + IE 5.2.
Thermocouple interuptor G60-ZUF10 Thermocouple Yellow Red cable thermocouple interuptor - receiver Magnetic valve GV-S60C/12 Gas valve mertik maxitrol GV 60 8 wired cable G6R-C5 Receiver G6R-R4AU Ignition cable 4mm ,1000mm 6.
installation, servicing and user instructions manual | GB + IE 33
Wanders fires & stoves Amtweg 4 7077 AL Netterden The Netherlands T: +31 (0) 315 - 386 414 F: +31 (0) 315 - 386 201 E: service@wanders.nl I: www.wanders.com garantiebewijs / guarantee certificate / certificat de garantie / garantieschein model / model / modèle / modell serienummer / serial number nr.
www.facebook.com/Wandersfiresstoves @Wanders_fires wandersfires wandersnetterden Type- en zetfouten voorbehouden. Wanders fires & stoves is een onderdeel van de Wanders Groep © 2014 Wanders Metaalproducten B.V. - All rights reserved Wanders fires & stoves Amtweg 4 7077 AL NETTERDEN Nederland Tel: +31 (0)315 - 386 414 Fax: +31 (0)315 - 386 201 info@wanders.nl www.wanders.