Operation Manual

30
5.2 Technical Data
Product Identication Number:
• 0359CO1364 for Danta,
• 0359CP1411 for Koto
5.2.1 Danta 500
Gas type
G20 G20/G25 G25 G20/G25 G30/G31 G31
I2H, I2E I2E+ I2L I2ELL
I3B/P
(30/50)
I3+
I3P
(37/50)
I3P (30)
Supply pressure mbar 20 20/25 25 20 30/50 28-30/37 37/50 30
Nominal heat input gross (Hs) kW 7,5 7,5 7,5 7,5 7,1 7,1 7,1 6,0
Nominal heat input nett (Hi) kW 6,8 6,8 6,8 6,8 6,6 6,6 6,6 5,5
Consumption m
2
/hr 0,711
0,711/
0,828
0,828 0,828 0,204 0,204 0,261 0,221
Burner pressure (hot) mbar 11,9
11,9/
18,75
18,75 18,75 28,3 28,3 36,0 29,1
Injector marking 280 (x2) 120 front, 100 rear
Pilot 440-1350-xx (31.2 inj) 440-1350-xx (27.1 inj)
Eciency class 2
Nox class 5
Type C11/C31
5.2.2 Danta 800
Gas type
G20 G20/G25 G25 G20/G25 G30/G31 G31
I2H, I2E I2E+ I2L I2ELL
I3B/P
(30/50)
I3+
I3P
(37/50)
I3P (30)
Supply pressure mbar 20 20/25 25 20 30/50 28-30/37 37/50 30
Nominal heat input gross (Hs) kW 10,0 10,0 10,0 10,0 8,4 8,4 8,4 7,2
Nominal heat input nett (Hi) kW 9,0 9,0 9,0 9,0 7,8 7,8 7,8 6,6
Consumption m
2
/hr 0,937
0,937/
1,09
1,09 1,09 0,234 0,234 0,304 0,261
Burner pressure (hot) mbar 14,8
14,8/
20,5
20,5 17,0 27,9 27,9 36,0 28,9
Injector marking 380 (x2) 400 (x2) 120 (x2)
Pilot 440-1350-xx (31.2 inj) 440-1350-xx (27.1 inj)
Eciency class 2
Nox class 5
Type C11/C31