Operation Manual

installation, servicing and user instructions manual | GB + IE
31
5.2.3 Danta 1100 & Koto
Gas type
G20 G20/G25 G25 G20/G25 G30/G31 G31
I2H, I2E I2E+ I2L I2ELL
I3B/P
(30/50)
I3+
I3P
(37/50)
I3P (30)
Supply pressure mbar 20 20/25 25 20 30/50 28-30/37 37/50 30
Nominal heat input gross (Hs) kW 13 13 13 13 10,8 10,8 10,8 9,3
Nominal heat input nett (Hi) kW 11,7 11,7 11,7 11,7 10,0 10,0 10,0 8,6
Consumption m
2
/hr 1,228
1,228/
1,4
1,4 1,4 0,303 0,303 0,399 0,344
Burner pressure (hot) mbar 16,0
16,0/
18,5
18,5 15 28,6 28,6 36,0 29,5
Injector marking 480 (x2) 560 (x2) 160 front, 120 rear
Pilot 440-1350-xx (31.2 inj) 440-1350-xx (27.1 inj)
Eciency class 2
Nox class 5
Type C11/C31
5.2.4 Danta 1400
Gas type
G20 G20/G25 G25 G20/G25 G30/G31 G31
I2H, I2E I2E+ I2L I2ELL
I3B/P
(30/50)
I3+
I3P
(37/50)
I3P (30)
Supply pressure mbar 20 20/25 25 20 30/50 28-30/37 37/50 30
Nominal heat input gross (Hs) kW 15,5 15,5 15,5 15,5 12,1 12,1 12,1 10,5
Nominal heat input nett (Hi) kW 14,0 14,0 14,0 14,0 11,2 11,2 11,2 9,7
Consumption m
2
/hr 1,447
1,447/
1,68
1,68 1,68 0,34 0,34 0,45 0,39
Burner pressure (hot) mbar 13,85
13,85/
21,3
21,3 16,0 25,2 25,2 35,0 26,2
Injector marking 560 front, 480 rear
650 front,
560 rear
160 (x2)
Pilot 440-1350-xx (31.2 inj) 440-1350-xx (27.1 inj)
Eciency class 2
Nox class 5
Type C11/C31