Instruction Booklet
12
and will pit the stainless steel. USE OF THESE PRODUCTS WILL
VOID THE WARRANTY.
3. Wipe faucet nozzle to remove any mineral deposits. A bristle
brush may be used to remove stubborn mineral build-up.
4. A ltering system is recommended to remove odors and inhibit
lime and scale build up in the unit.
5. In areas with extremely hard water, a water softener must be
installed in order to prevent a malfunctioning of equipment and
in order not to void the warranty.
DAILY
Wipe the outside of the unit with a damp cloth, using soap solution
or a nonabrasive compound when required.
TROUBLESHOOTING CODES
During operation under certain conditions, your machine may display
one of the following error codes. Please follow the chart below to x.
Error
Code
Cause Solution
Contact a Service Center if the following error codes appear
E-1
Internal temperature control
damage.
Call a service center for repair or adjustment.
E-2
Machine malfunction. Call a service center for repair or adjustment.
E-3
Heating element damage. Call a service center for repair or adjustment.
E-4
Issue with upper water level
sensor.
Call a service center for repair or adjustment.
E-5
Issue with lower water level
sensor.
Call a service center for repair or adjustment.
User Fixable
E-6
Hot water dispenser does
not have enough water to
begin heating.
Connect to a water source or switch to manual
mode and pour water into the hot water dispenser.
Once water is at proper ll level, alarm will stop and
the machine will begin heating.
Ensure hot water dispenser is on a level surface.
E-7
Water level is too low. Ensure the connection to the water supply is
open and water line pressure is running properly.
If the problem persists, consult customer service
or a local service center.