Installation Guide

4
The Heating Roll
A. Heating Element
B. Fiberglass Mesh
C. Tape
D. Cold Lead Wire
E. Factory Splice
F. Floor Sensor (optional)
The Heating Element
The Heating Element consists of two copper alloy resistance wires covered by Teon™ insulation. A braided metal
surrounds the primary Teon™ insulation and serves as ground sheath. The Heating Element (A) attached with tape
(C) in a serpentine pattern to a exible Fiberglass Mesh (B). The Fiberglass Mesh is designed to keep the Heating
Element evenly spaced throughout the roll. The cold lead return wire is factory installed at one end of the Heating
Roll and must run back to the power supply along the perimeter of the heated space. The power lead (D) is 15-feet in
length. The lead is spliced to the Heating Element (E) at the factory. If necessary, this lead wire may be shortened or
even extended. Please note the thickness of the factory splice and cold lead and plan accordingly.
Floor Sensor (not required for all systems)
Systems using a SmartStat Programmable Thermostat or EasyStat require a Floor Sensor (G). This Sensor is embedded
in the oor and monitors the oor temperature. The Floor Sensor should be centered in between 2 resistance wires
leaving approximately 1.5” on either side and extend about 6” into the heated area. Avoid placing the sensor in an
area affected by a draft, a radiator or the sun. Must be installed if using a thermostat. Some people choose to install a
second (Backup) sensor. For an additional cost you may purchase a second sensor.
Relay Contactor or Power Modules
(not required for all systems)
Systems installed in large spaces will most likely require a Relay
Contactor or Power Module(s) in addition to the control device
to operate properly. The Relay or the Power Modules may be
located in the same vicinity as the control device. If your system
will be using this option, all cold leads will be connected to the
relay contactor or power module and not directly to the control
device.
Heating Roll(s): Types and Sizes
Roll(s) are rated at 15-watts per square foot and vary in length.
Each roll is designed to draw a specic amount of electricity
and therefore produce the proper amount of heat based on its
length. For this reason, the length of the roll(s) can never be
shortened to make a proper t. Your Installation Plan has been
designed to specically accommodate your space. The same is
true for rooms that have multiple rolls. Multiple rolls are never
wired to each other. Each roll is wired in parallel to the control
device or relay contactor.
Working with the Heating Roll(s)
The roll(s) that make up your system have been selected to
t into your oor plan. The Installation Plan shows precisely
where each roll starts and ends. The “Lead Wire” on each roll
is designed to travel back to the control device location. These
wires do not heat. All connections are made at this point. While
it may be required to cut and alter the “Fiberglass Mesh”, the
“Heating Element” must stay intact. Page 5 shows in detail
how to make the necessary turns to install your Floor Heating
System.
Separating the Heating Element
from the Mesh
During the installation, you may need to separate the Heating
Element from the Fiberglass Mesh. This can be done provided
the Heating Element is not cut and the shielding is not nicked
or punctured. It will be necessary to do this when releasing the
Heating Element to make step turns and position it in a “Free
Form” space.
E
F
Warmlyyours Floor Heating System.
C/O INDIA Made by Thermopads Pvt. Ltd. for WarmlyYours.com Inc.
ENREGISTRE
LISTED
C
US
RADIANT HEATING PANEL UNIT
UNITE DE PLANCHER
CHAUFFANT ELECTRIQUE
8PA5
TempZone Electric Floor
Heating Panel
Plancher Chauffant Electrique
For installation in an
adhesive bed, self leveling or
mortar cement
Installation avec ciment, mortier
colle ou colle a carrelage
SKU S/NO
Resistance / Ohm Spez. output W/sqf
Puissance au pied carre : 15 W
Core to Core : 105.3 Ohm Voltage : 120V/60 Hz
Tension a Te nsion Length / ft
Grd Sheath to Grd Sheath : 1.02 Ohm Longueur en pieds : 9
Prise de terre a Pdt Width / ft
Largeur en pieds : 1.0
Output Unit W : 135
Puissance de l’unite
Secondary Teon
Insulation
Primary Teon
Insulation
Multi Strand
Conductor Wire
Metal Braiding
Connected to Ground