Installation Guide

Example of Wiring a Control to Twin Conductor
8
Twin Conductor
Turn off Breaker
1. Using a wirenut, attach line (240V) or neutral (120V)
from breaker box to top, red wire on the thermostat
labeled: “L2(N)”.
2. Using a wirenut, attach line (240V & 120V) from
breaker to bottom, black wire labeled: “L1(L)”.
3. Using a wirenut, attach red wire (yellow for 120V)
from heating, roll to the lower, red wire labeled: “load
”.
4. Using a wirenut, attach black wire to upper black
wire labeled: “Load ”.
5. Using a wirenut, attach the ground wire of heating
roll to the ground wire in the wallbox.
6. Turn on breaker.
Black
HOT
FROM POWER SOURCE 120V & 240V
HOT (240V) or
NEUTRAL (120V)
HOUSE GROUND
Red (240) or
Yellow (120) Wires
Red
Black
Red
Copper
Ground
Black Lead
THERMOSTAT
1
2
3
4
5
C/O INDIA Made by Thermopads Pvt. Ltd. for WarmlyYours.com Inc.
ENREGISTRE
LISTED
C
US
RADIANT HEATING PANEL UNIT
UNITE DE PLANCHER
CHAUFFANT ELECTRIQUE
8PA5
TempZone Electric Floor
Heating Panel
Plancher Chauffant Electrique
For installation in an
adhesive bed, self leveling or
mortar cement
Installation avec ciment, mortier
colle ou colle a carrelage
SKU S/NO
Resistance / Ohm Spez. output W/sqf
Puissance au pied carre : 15 W
Core to Core : 105.3 Ohm Voltage : 120V/60 Hz
Tension a Te nsion Length / ft
Grd Sheath to Grd Sheath : 1.02 Ohm Longueur en pieds : 9
Prise de terre a Pdt Width / ft
Largeur en pieds : 1.0
Output Unit W : 135
Puissance de l’unite
Secondary
Flouropolymer
Insulation
Primary
Flouropolymer
Insulation
Solid
Conductor
Wire
Metal Braiding
Connected to Ground
Double Gang Box with a
Single Gang Mudring
Load
L2 (N)
L1 (L)