Example of Wiring a Control to Twin Conductor
Twin Conductor
Turn off Breaker
1. Attach line (240V) or neutral (120V)
from breaker box to the terminal screw
on the line side labeled “3 / L2(N)”
2. Attach line (240V & 120V) from
breaker to the terminal screw on the
line side labeled “2 / L1(L)”
3. Attach red wire (yellow for 120V)
from heating, roll to the terminal
screw on the load side labeled “4”
4. Attach black wire from heating roll
to the terminal screw on the load side
labeled “1”
5. Using a wirenut, attach the ground
wire of heating roll to the ground wire
in the wallbox.
6. Turn on breaker.
8
ENSURE THE SYSTEM
IS GROUNDED
HOUSE GROUND
BRAIDED GROUND SHEATH
COLD LEAD
BLACK WIRE
RED 240V
or
YELLOW 120V
REAR OF THE BASE
HOT (240V) or
NEUTRAL (120V)
HOT
FROM
POWER
SOURCE
FLOOR
FRONT OF THE BASE
FLOOR SENSOR
LOAD
14
2
3
L1(L)
L2(N)
LINE
1800W/3600W MAX 15A
120/240VAC
FROM
POWER
FLOOR
LOAD
1
4
2
3
L1(L)
L2(N)
LINE
1800W/3600W MAX 15A
120/240VAC
BR1015A10b
© 2015 OJ Electronic A/S
A B C D
out
in / sensor
in / sensor
A
B C
D
ou
t
in / sensor
in / sensor
Twin Conductor
Turn o Breaker
1. Attach line (240V) or neutral (120V)
from breaker box to the terminal screw
on the line side labeled “3 / L2(N)”
2. Attach line (240V & 120V) from
breaker to the terminal screw on the
line side labeled “2 / L1(L)”
3. Attach red wire (yellow for 120V)
from heating, roll to the to the terminal
screw on the load side labeled “4”
4. Attach black wire from heating roll
to the terminal screw on the load side
labeled “1”
5. Using a wirenut, attach the ground
wire of heating roll to the ground wire
in the wallbox.
6. Turn on breaker.