Step 1 
Draw a diagram of the preferred location of the brackets and the electrical 
connection on the Towel Warmer box to create a template (see Step 2 for 
template instructions). At least two of the four brackets must be attached 
directly to a stud.
The  Innity  Plug-In  model  must  be  installed  less  than  6’  (183cm)  from 
a properly  grounded outlet  to ensure the  plug can reach.  Make sure to 
measure the distance from where to plug is attached to the Towel Warmer to 
the electrical outlet. Do NOT use an extension cord to make the connection 
between the Towel Warmer plug and outlet.
Step 2
A. Attach tubing into desired positions on the Towel Warmer (see pages 5-6 
for bracket assembly).
B. Place Towel Warmer on the box (or a large sheet of paper) and lay on a 
at surface with brackets facing downwards.
C. Mark the location of the following:
  • The electrical collar (Hardwired model only).
  • The location of the brackets.
D. Use the template as a guide to mark the wall with the correct locations 
of the four brackets, ensuring the following:
  • The electrical collar is lined up with the center of the electrical 
box (Hardwired model only). Plug-in model must be installed less 
than 6’ (183cm) from properly grounded outlet. Do NOT use an 
extension cord.
  • At least two of the brackets are lined up with a wall stud.
  • The Towel Warmer is level.
Step 3
Install the brackets onto the wall. Use the drywall anchors that are supplied 
for the brackets that are not being installed into a stud. Refer to Diagram 
A and B.