5.0 TESTING THE MATS AND CABLE
5.1 TEST ONE: TOTAL CABLE RESISTANCE
(MULTI-METER REQUIRED)
1. Connect one meter clamp to one cold lead (pigtail) inner conductor and the
other meter clamp to the other cold lead (pigtail) inner conductor.
2. Test in accordance with the meter manufacturer’s instructions and record this
ohm value on the warranty card on last page.
3. Total nominal cable resistance information is found on the CSA label, the bill of
materials and Appendix A and Appendix B, or can be obtained by calling your
WarmlyYours Account Manager. Actual reading should be within 10% of the
cable resistance.
4. Record measured values on the warranty card on last page. Perform this test
before, during and after installation of the Heating Cables.
5. Please be sure that you write in the full part number of the Cable or Mat next to
your results.
5.2 TEST TWO & THREE: INSULATION RESISTANCE
(MEGOHMMETER REQUIRED)
1. Connect one meter clamp to the cold lead (pigtail) inner conductor and the
other meter clamp to the yellow/green (ground) of the Heating Cable.
2. Test in accordance with the meter manufacturer’s instructions. Recommended
meter is a 500 VDC megohmmeter.
3. Megohmmeter reading should read “innite”.
4. Record measured values on the warranty card on last page. Perform this test
before, during and after installation of the Heating Cables.
5. Duplicate test using inner conductor.
6.0 WARRANTY
WarmlyYours provide a warranty for the Heating Cables for a period of 10 years
from date of purchase, for the material and workmanship under normal operating
conditions.
In case of defective material, WarmlyYours obligation will be limited to the repair
or supply of new material, free of charge to the customer.
The warranty does not cover installations made by unqualied persons or faults
caused by incorrect design by others / misuse / damage caused by others /
damage in transit / incorrect installation and any other subsequent damage that
may occur. Costs related to repair / replacement will be fully chargeable to the
customer if the damage is due to of any of the above reasons.
WarmlyYours is under no circumstances liable for consequential damages or
losses including without limitations the loss or prot arising from any cause
whatsoever. The guarantee is a material warranty only and does not cover eld
labor.
The warranty is void if there is any payment default and if data is not lled in
attached warranty card.
WARNING
Heating cable may hold a charge after the 500 VDC tests. Allow time for charge to
dissipate before handling the heating cable afterward.
Yellow
or Red
Ground
Ground
Yellow
or Red
Black
Black
Core
Ground
Ground
Core
Core
Core
TEST #1
Ohms Test with
Multimeter
TEST #2
Insulation Ohms with
500 VDC megger
(Innite is good value)
TEST #3
Insulation Ohms with
500 VDC megger
(Innite is good value)