Installation Manual

4ft
(1.2m)
°C
21.5
Wed 15 Feb
12:38PM
22.0 until
12:45pm
22.2
Language
English
°C
21.5
Wed 15 Feb 12:38PM
22.0 until
12:45pm
22.2
1
3
6
5
8 9
4
7
2
‘MyHeating’
by Warmup
1. Isolate the 6iE and supply from the mains supply.
2. Unclip the display from the power base and remove
the display
3. DO NOT install the 6iE near a window/door, in direct
sunlight or above another heat generating device (e.g.
radiator or TV).
4. Ensure distance from the router to 6iE is not
excessive to reduce range or interference issues.
5. Install a 3-1/2” (89 mm) deep single gang or 2-gang
box with mud ring in your preferred thermostat
location. Pull wires (heater, supply and sensor) through
gang box and complete terminal wiring. Insert xing
screws through mounting holes of the power base and
tighten.
6. Re-attach the display to the power base and switch
on the 6iE. Follow the on screen instructions to set up
the system. Once set up a QR Code will appear.
NOTE: The function of Probe 1, Probe 2 from Control/
Limit Sensor can be swapped in Advanced Settings;
Sensors & Application.
7. Download the MyHeating App.
Technical Specications
8. Open the MyHeating App and scan the QR Code on
the 6iE screen and follow the instructions in the App to
complete setup.
9. Scan the QR Code for full online user guide.
The 6iE must be installed by a qualied electrician
in accordance with National Electrical Code.
LOAD L1 & L2 Heater Load Max.15A
(1800W/120V, 3600W/240V)
LINE L1 Supply Live (120 V)
LINE L2 Supply Neutral (120 V) /
Supply Live (240 V)
P1 & PC Probe 1 - Floor/Air Control Sensor
(No Polarity)
P2 & PC Probe 2 - Limit Sensor (No Polarity)
WIRING CONNECTIONS
EN
#
Use Case Control Limit Sensor
Cas d’utilisation Contrôle Sonde de limitation
Caso de uso Control Sensor de límite
1
A1
B1
C3
X
2
*
A3
B2
C1
P1 & PC
X
3
A1
B2
C2
P1 & PC
4
A2
B1
C3
P1 & PC
X
5
**
A1
B1
C1
P2 & PC
Thermostat in room
Termostato en la habitación
Thermostat dans la pièce
Thermostat in/out of room
Termostato dentro / fuera de la habitación
Thermostat dans/hors de la pièce
Air temperature schedule
Temperatura del aire programación
Programme de température de l’air
Floor temperature schedule
Programa de temperatura del suelo
Programme de température du sol
Floor limit
Límite del suelo
Limite de sol
Air limit
Límite de aire
Limite de air
No oor limit
Sin límite de suelo
Pas de limite de sol
Thermostat out of room
Termostato fuera de la habitación
Thermostat hors de la pièce
A1
A3
B1
B2
C1
C2
C3
A2
Internal air sensor
Sensor de aire interno
Sonde d’air interne
Recommended when thermostat is
out of the heated room
Recommandé lorsque le thermostat
est hors de la pièce chauée
Recomendado cuando el termostato
está fuera de la habitación
climatizada
Recommended when thermostat is
in the heated room
Recommandé lorsque le thermostat
est dans la pièce chauée
Recomendado cuando el termostato
está en la habitación climatizada
Air sensor
Sensor de aire
Sonde d’air
Floor sensor
Sensor de suelo
Sonde de sol
Model 6iE-XX-YY-ZZ
Voltage 110V - 240V AC +/-15% 50Hz/60Hz
Protection II
Max. Load
15A resistive (120 V/1800W,
240 V 3600W)
GFCI Class A GFCI with 5mA trip level
Rated impulse voltage 4000V
Automatic action 100,000
Disconnection means 1B
Pollution degree 2
Max. Ambient
Temperature
40°C / 104°F (T40)
Relative Humidity 80 %
IP Rating IP30
Sensors Floor/Air
Sensor Type NTC10K @ 25°C
Operating Frequency 2401 - 2484MHz
Max. Radio-Frequency
Power Transmitted
20dBm
Compatibility Electric underoor heating
Standards
UL-60730-1
UL-60730-2-9
UL-943
CAN/CSA-E60730-1
CAN/CSA-E60730-2-9
CAN/CSA-C22.2 No. 144.1
FCC 47 CFR Part 15, ICES-003
Table 1.0 / Tableau / Tabla 1.0
2
*
5
**
Please see Table 1.0 for thermostat use cases.