Specification

The world’s best-selling electric floor heating brand
DCM-PRO PEEL-AND-STICK MEMBRANE
SUBMITTAL SHEET WSC - 1001
WARMUP INC.
USA: us@warmup.com
Tel.: 1-888-927-6333
www.warmup.com
CANADA: ca@warmup.com
Tel.: 1-888-592-7687
www.warmup.ca
The world’s best-selling electric floor heating brand
PRODUCT CODE
•DCM-PS-80, box of sheets to cover 80 sf
•DCM-PS-150, roll to cover 150 sf
•DCM-PWS-80, box of sheets to cover 80 sf
•DCM-PWS-150, roll to cover 150 sf
PRODUCT DESCRIPTION
The TCNA-tested DCM-PRO Peel-and-Stick Membrane can be installed directly onto clean plywood and concrete suboors
without thinset. The patented DCM-PRO design allows for more adhesive to cable contact ultimately distributing heat faster
and more evenly. There is no waiting required after installation so you can begin laying the ooring immediately. The DCM-PRO
Membrane is ready to tile.
For ease, installers can cut the membrane to size, peel back the protective lm, and stick the membrane directly onto a
plywood or concrete suboor. Installers can use either modied or unmodied adhesives over the membrane to suit their
installation needs. The DCM-PRO Peel-and-Stick Membrane can also be covered with self-levelling mortars (SLU’s) to allow
installation of small format tiles and other oor types such as glue-down wood and LVT’s, to be laid on top of the DCM-PRO
System. The unique design of the DCM-PRO Membrane protects the cable from installation damage, reducing the risk of cable
failure.
The DCM-PRO Peel-and-Stick Membrane has been successfully tested to ANSI 118.12 standards and performed well on the
Robinson test (ASTM C-627). It is the highest-rated membrane for oor heating systems and the rst of its kind to adhere
without the use of thinset.
FEATURES
Under 6mm – 1/4” thick
Rated as Anti-Fracture membrane as tested by the TCNA against
ASTM 118-12
Installs directly to suboor, without thinset
Ready to tile over
Use any adhesives or SLU’s on top for ooring installations
APPLICATION
The DCM-PRO Peel-and-Stick Membrane can be installed directly over a clean plywood or concrete suboor without thin-
set. To prevent dust and similar to impede bonding, the application of a Solvent-Free primer is highly recommended prior
to sticking down the membrane. For uneven oors such as som OSB’s or old suboors with residue, the Fleece-backed “M”
membrane may be advisable.
Always follow installation instructions and shop-vac/wet-mop the suboor for effective bonding.
The Warmup DCM-PRO Cable can be installed at varius spacing to achieve the desired heat output. See chart.