Installation Manual

4ft
(1.2m)
1
3
5
8 9
4
7
2
‘MyHeating’
by Warmup
1. Isolate the thermostat from the mains supply.
2. Unclip the display from the power base and remove
the display
3. DO NOT install the thermostat near a window/door,
in direct sunlight or above another heat generating
device (e.g. radiator or TV).
4. Ensure distance from the router to thermostat is not
excessive to reduce range or interference issues.
5. Install a 3-1/2” (89 mm) deep single gang or 2-gang
box with mud ring in your preferred thermostat
location. Pull wires (heater, supply and sensor) through
gang box and complete terminal wiring.
6. Insert xing screws through mounting holes of the
power base and tighten. Re-attach the display to the
power base and restore power to the thermostat.
Follow the on screen icons to set up your system.
NOTE: The function of Probe 1, Probe 2 from Control/
Limit Sensor can be swapped in settings.
7. Download the MyHeating App.
Technical Specications
8. Open the My Heating App and scan the QR
Code on the thermostat screen protector/reverse of
the display and follow the instructions in the App to
complete setup.
9. Scan the QR Code for full online user guide.
The thermostat must be installed by a
qualied electrician in accordance with National
Electrical Code.
LOAD L1 & L2 Heater Load Max. 15A
(1800W - 120 V, 3600W - 240 V)
LINE L1 Supply Live (120 V)
LINE L2 Supply Neutral (120 V) /
Supply Live (240 V)
P1 & PC Probe 1 - Floor/Air Control Sensor
(No Polarity)
P2 & PC Probe 2 - Limit Sensor (No Polarity)
WIRING CONNECTIONS
EN
Model RSW-XX-YY-ZZ
Voltage 110V - 240V AC +/-15% 50Hz/60Hz
Protection II
Max. Load
15A resistive
(120 V - 1800 W
240 V - 3600 W)
GFCI Class A GFCI with 5mA trip level
Rated impulse voltage 4000V
Automatic action 100,000
Disconnection means 1B
Pollution degree 2
Max. Ambient
Temperature
40°C / 104°F (T40)
Relative Humidity 80 %
IP Rating IP30
Sensors Floor/Air
Sensor Type NTC10K @ 25°C
Operating Frequency 2401 - 2484MHz
Max. Radio-Frequency
Power Transmitted
20dBm
Compatibility Electric underoor heating
Standards
UL-60730-1
UL-60730-2-9
UL-943
CAN/CSA-E60730-1
CAN/CSA-E60730-2-9
CAN/CSA-C22.2 No. 144.1
FCC 47 CFR Part 15, ICES-003
Thermostat application
#
Use Case Control Limit Sensor
Application du thermostat Cas d’utilisation Contrôle Sonde de limitation
Aplicación de termostato Caso de uso Control Sensor de límite
1
A1
B1
C3
X
2
*
A3
B2
C1
P1 & PC
X
3
A1
B2
C2
P1 & PC
4
A2
B1
C3
P1 & PC
X
5
**
A1
B1
C1
P2 & PC
1,500W
90%
Electric underoor heating
Chauage au sol électrique
Suelo radiante eléctrico
Thermostat in room
Thermostat dans la pièce
Termostato en la habitación
Thermostat in/out of room
Thermostat dans/hors de la pièce
Termostato dentro / fuera de la habitación
Air temperature schedule
Programme de température de l’air
Temperatura del aire programación
Floor temperature schedule
Programme de température du sol
Programa de temperatura del suelo
Floor limit
Limite de sol
Límite del suelo
Air limit
Limite de air
Límite de aire
No oor limit
Pas de limite de sol
Sin límite de suelo
Thermostat out of room
Thermostat hors de la pièce
Termostato fuera de la habitación
Electric + relay
Électrique + relais
Electrico + rele
Input wattage
Puissance d’entrée
Potencia de entrada
Input eciency
Ecacité d’entrée
Eciencia de entrada
Coventional
Conventionnel
Convencional
Hydronic underoor heating
Plancher chauant hydraulique
Suelo radiante hidrónico
6
A1
A3
B1
B2
C1
C2
C3
A2
Internal air sensor
Sonde d’air interne
Sensor de aire interno
Air sensor
Sonde d’air
Sensor de aire
Floor sensor
Sonde de sol
Sensor de suelo
3
See thermostat applications. Scan QR code, step
9, for online user guide which contains additional
thermostat applications.
Recommended when thermostat is in
the heated room
Recommandé lorsque le thermostat
est dans la pièce chauée
Recomendado cuando el termostato
está en la habitación calefactada
Recommended when thermostat is out
of the heated room
Recommandé lorsque le thermostat est
en dehors de la pièce chauée
Recomendado cuando el termostato
está fuera de la habitación calefactada
2
*
5
**
Warmup - IM - Terra - V1.1 2021-09-09_NA-ML.indd 2Warmup - IM - Terra - V1.1 2021-09-09_NA-ML.indd 2 10/09/2021 16:40:4910/09/2021 16:40:49