Terra TM WiFi Thermostat Smart Heating. Simplified.
Pack Contents x1 x1 x2 x1 Contents Safety Information............................................................................................. 3 Step 1 - Installation............................................................................................ 3 Step 2 - Wiring Connections............................................................................. 4 Table 1.0 Thermostat Use Cases .............................................................................. 5 Wiring Diagrams ......
Safety Information q The thermostat must be installed by a qualified electrician. It requires a permanent 110V - 240V AC, 60Hz supply. The thermostat contains a Class A GFCI with 5mA trip level and wiring must conform to local electrical code. q Isolate the thermostat from the mains supply throughout the installation process. q Install the thermostat in an area with good ventilation. It should not be beside a window/door, in direct sunlight or above another heat generating device (e.g. radiator or TV).
Step 2 - Wiring Connections WARNING! The thermostat must be installed by a qualified electrician in accordance with National Electrical Code. Wiring Connections LOAD L1 & L2 LINE L1 LINE L2 P1 & PC P2 & PC Heater Load Max.15A (1800W - 120V, 3600W - 240V) Supply Live (120 V) Supply Neutral (120 V) / Supply Live (240 V) Probe 1 - Floor/Air Control Sensor (No Polarity) Floor or air temperature reading for scheduled control Probe 2 - Limit Sensor (No Polarity) See Table 1.
Table 1.
Wiring Diagrams Heating loads connected to thermostat Hot 120V or Neutral Hot 120V 20 A Heating ≤ 3600W/15A Option 1 Heating ≤ 3600W / 15A into thermostat only R C Snubber not required RED - Hot 120V / White - Neutral Heating, RED - 240V, Yellow - 120V Heater earth connections should be connected to earth in line with NEC, CEC code.
Wiring Diagrams Heating loads connected to Relay-25 Snubber Hot 120V or Neutral Hot 120V R C 20 A 8 2 6mA GFCI 20 A 4 6 1 0 Relay 1 ≥ 15 A Heating ≤ 3600W/15A Option 2 Heating ≤ 3600W / 15A into external relay only R C Snubber required RED - Hot 120V / White - Neutral Heating, RED - 240V, Yellow - 120V Heater earth connections should be connected to earth in line with NEC, CEC code.
Wiring Diagrams Heating loads connected to thermostat and Relay-25 Snubber Hot 120V or Neutral Hot 120V R C 20 A Heating ≤ 3600W/15A 8 2 6mA GFCI 20 A 4 6 1 0 Relay 1 ≥ 15 A Heating ≤ 3600W/15A 8 2 6mA GFCI 20 A 4 6 1 0 Relay # ≥ 15 A Heating ≤ 3600W/15A Option 3 Heating ≤ 3600W / 15A into thermostat Heating ≤ 3600W / 15A into external relay Additional relays can be added to circuit as shown R C Snubber required RED - Hot 120V / White - Neutral Heating, RED - 240V, Yellow - 120V Heater
Step 3 - Thermostat Mounting 2 1 1,500W Insert fixing screws through mounting holes of the power base and tighten. 3 System type Input wattage 1,500W Re-attach the front housing until a “click” is heard. You can now power up the thermostat. Input efficiency Thermostat application (1-12). See table 1.0 WiFi Setup Open MyHeating app.
Step 4 - Initial Setup 2 1 ‘MyHeating’ by Warmup Download the MyHeating App. Open the MyHeating App and scan the QR Code on the thermostat screen protector or on reverse of the display. Follow the instructions in the App to complete setup.
Welcome to the Terra thermostat Next/Accept Back/Cancel Up/Down Change value/setting How to quickly change the temperature Press / to change your target temperature. If in program mode this will set a temporary override until your next heating period. See “How to set a temporary override”. 70 If in manual mode this will set a fixed target temperature.
Heating How to set a program Setting a program allows you to set comfort temperatures at set times throughout the day. Days can programmed individually, all days the same or weekdays as a block and weekends as a block, the choice is yours. 70 Edit Program 7 1234567 07:00AM 09:00AM 04:30PM 09:00PM 70 70 07:00 70° 09:00 + + To select the days you wish to program press / . A bar will appear below the day of the week. Press to move to the next day. Press to set a program.
Heating How to set into Manual Mode Setting into manual mode allows you to set a fixed target temperature for the thermostat to achieve. The thermostat will continue to maintain this temperature until another operating mode or temperature is selected. 70 73 --- 73° --- 73 Sets the target temperature indefinitely. Set the duration of the manual mode.
Energy Monitor How Energy Monitor works The thermostat learns how you use your system and how your house reacts to heating and weather. Using the MyHeating App, energy monitoring will show the amount of energy consumed over a certain time period. This will be calculated through system power multiplied by efficiency and run time. You will need to enter the power of your system, and in some cases, the efficiency. If you do not know these, speak to your installer or system manufacturer.
Settings 70 Date and time Set the current date and time. Press to begin, press / to change date/time. Press to confirm. 6-5-2021 13:00 Thermostat application 1 2 Swaps probe usage, 1 being the Control Sensor Probe and 2 being the Limit Sensor Probe. Press / to swap probe usage. Press to confirm. Press 3 1 10K 2 10K See Table 1.0 Thermostat Application. / to change application. Press confirm. Change Control Sensor Probe 1 (5 & 6) type. Set between 5, 10, 12, 15, 100K sensor settings.
Settings cont’d Change homescreen override color Select the override color. Open window function The windows open detection feature is designed to switch off heating to save energy when the thermostat detects that a window or door has been opened. Display lock Switch display lock on. 0000 Set display lock code. Switch display lock off. WiFi WiFi Setup Open MyHeating App and scan the QR code on the back of the thermostat display to complete WiFi setup.
Notifications & Error codes Date and time needs to be set. Heating switched OFF Open window function triggered. Display locked Temporary override enabled 2 Sensor P2 (6 & 7) error Holiday mode enabled. --- Frost protect enabled. ! (Configured in MyHeating App) (Configured in MyHeating App) GFCI tripped GFCI -- - GFCI Power (Electrician Required) Electrician required to verify power is going to the thermostat and that it is correctly wired. Control (5 & 6) / Internal Air sensor error 1.
Troubleshooting cont’d Clock Icon Time and Date not set Connect the thermostat to a WiFi network or alternatively set the time and date from the settings menu. GFCI Icon GFCI test button The GFCI feature is used to detect any leakage of current from your heating system. During a ground fault the two lines of the load will be cut off.
WiFi Troubleshooting Before following the troubleshooting guide below please check the following: 1. The password is WPA2 protected. 2. The router is set to a 2.4 GHz band. (802.11 b, g, n, b/g mixed, b/g/n mixed) NOTE: If you need to change any of the items listed above, please refer to your router manual. Thermostat won’t connect/lost connection to WiFi Network Possible connection timeout. In the MyHeating App try to connect YES to the WiFi Network again.
Technical Specifications Model RSW-XX-YY-ZZ Operating Voltage 110V - 240V AC +/-15% 50Hz/60Hz Protection Class II 15A resistive (120 V - 1800W, 240 V - 3600W) Max. Load GFCI Class A GFCI with 5mA trip level Rated impulse voltage 4000V Automatic action 100,000 Disconnection means 1B Pollution degree 2 Max. Ambient Temperature 40°C / 104°F (T40) Relative Humidity 80% IP Rating IP30 Sensors Floor/Air Sensor Type NTC10K @ 25°C Operating Frequency 2401 - 2484MHz Max.
R LIMITED YEA W A 12 U P 12 RR RM AN 12 TY P TY AN RR WA Warmup warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of twelve (12) years from the date of purchase by the consumer when installed with a Warmup heater. WAR M U Warranty YE A R LI M ITE D W A If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option.