Operating instructions

raised. The adaptive function finds out when the
thermostat shall start heating to ensure that the
right temperature is reached at the t ime that it
has been programmed for.
6.7.4. Offset
Offset is used to compensate for any difference
between the thermostat and a room
thermometer. If the thermometer, for instance,
shows 1°C more than the thermostat, it is
possible to adjust the offset by +/- 5°C. Then
the thermostat will show the same temperature
as the thermometer. If the thermostat for
example shows 1 degree too much, offset
should be set to +1. Then the temperature will
be set 1 degree lower.
Offset applies to both built-in and external
sensors whereas the limit sensor, if any, is not
affected.
6.7.5. Fil Pilote*
Here you can specify temperature settings that
will depend on which signal is received from the
Fil pilote input.
*Please note: The Fil pilote menu is only
available in type WA-STAT-VB. It is primarily for
usage in France.
Eco Temp: Economic temperature
Frost Prt T: Frost protection
Fil Pilote: On/Off
6.7.6. Reset
Reset 2: Reset values defined in Engineer
settings to factory settings.
Reset 3: Equal to Reset 2, except history
data are deleted. The number of relay
connections is not deleted, though.
7. Error Messages
If you get an error the LED is flashing red.
Internal
failure Contact Warmup
External
failure Contact Warmup
Day 1-5
Event
Time With floor sensor With air sensor
Day 06:00-08:00 25°C 20°C
Out 08:00-16:00 20°C 15°C
Home 16:00-22:30 27°C 22°C
Night 22:30-06:00 20°C 15°C
Day 6-7
Event Time
With floor sensor With air sensor
Day 08:00-23:00 27°C 22°C
Night 23:00-08:00 20°C 15°C
8. Factory settings
The thermostat is delivered with factory set programs as follows:
Tiles Stone Laminate Wood Carpet Vinyl Other
Wire
YES YES NO NO NO NO n/a
Ribbon Wire
YES YES YES YES NO NO n/a
Carbon
YES YES YES YES YES YES n/a
Central heating
n/a n/a n/a n/a n/a n/a n/a
Type A
YES YES NO NO NO NO n/a
Type B
NO NO YES YES NO NO n/a
Type C NO NO NO NO YES YES n/a
User Defined
n/a n/a n/a n/a n/a n/a n/a
Tiles Stone Laminate Wood Carpet Vinyl Other
Wire
A A n/a n/a n/a n/a H
Ribbon Wire
A A B B n/a n/a H
Carbon
A A B B C C H
Central heating
G G G G G G H
Type A
D D n/a n/a n/a n/a H
Type B
n/a n/a E
E
n/a n/a H
Type C n/a n/a n/a n/a F F H
User Defined
H H H H H H H
Configuration Control temperature Overheat
Room Floor
Min. Max.
Min. Max. Max.
A 5 40 5 40 40
B 5 27 5 27 30
C 5 25 5 25 30
D 5 40 5 50 55
E 5 27 5 45 50
F 5 25 5 35 40
G 5 45 n/a n/a
H prog prog prog
9. Appendix
9.1. Table of Compatibility
9.2. Heat Definitions
n/a = not available