SDS
Place three undischarged and unconditioned batteries in a series with one test sample battery reversed,
Complete the circuit until vent activation or until the temperature of the reversed battery returns to ambient.
Requirement) The batteries should be no explosion during this test.
9.6) Safety Test Results.
No. n
1 5
2 5
3 5
4 5set
5 5set
Manager
Check
Approval
JunPing Liu
Lihui Chen
HangJun Wu
* N.L : Not Leakage / N.E : Not Explode
Tel:086-0755-29957377
http://www.allkeybattery.com
Overdischarge
(Mixed use)
New battery is
series connect with
used one, and
discharge to (n X the
number battery)
N.E
N.E
Incorrect
installation
Place three
batteries in a series
with one test sample
battery reversed
N.E
N.E
Climatic cycling
Batteries storage -
20~70℃ cycling
chamber. The
cycling is 10 times.
N.E
N.E
External Short
Circuit
Battery is
connected with
wire directly +/-
polarity. 24hours
connecting.
N.E
N.E
9.5) Incorrect installation
Test Item
Method
Criteria
Result
Partial
Use
Discharge to 50%
of MAD (5.1Ω-
continuous) and
storage 30days at 45
± 5 ℃
NL/NE
NL/NE
undischarged batteries. One undischarged battery is discharged under service output test condition (R1),
then three undischarged batteries and one discharged battery of the same brand, same type and origin shall
be connected in series. The discharged shall be continued until the total on load voltage falls to four times
(n X 0.6V; n is the number of batteries). The value of the on-load resistor (B1) shall be approximately four
times the lowest value from the resistor R1.
Requirement) The batteries should be no explosion during this test.
Part No.
ALLKEY--LR03-2017
Page
9/9
9.4) Over discharge ( Battery mix-up fresh & used or other type battery)
This test simulates the condition when one discharged battery is series-connected with three other
Approved Date
2017/1/3
Part Name
Alkaline Primary Battery - LR03
Version
C/0
SPECIFICATIONS
Prepared Date
2017/1/3
4/F, Hongwan Commercial Building, 4235# Bao'an
District,518126, Shenzhen