Owner's manual

10
Warner Electric 800-825-9050 819-9050
Programming
Line
1 The number that is downloaded to the display when the marker pulse is detected.
2 The first brake distance used by the CBC-1000 at power-up.
3 The number of cycles used for the running average of brake distance.
4 The scaling factor for the front panel display (0.5000 for display in pulses).
5 Number of decimal points displayed. Affects all distance values in other registers.
6 Enables or disables front panel reset in the Run Mode.
7 "On" enables and "Off" disables changing MOV PST, E.W., and BCH PST while running.
8 Retains system position during power off.
9 Select Absolute (ON) or Incremental (OFF) mode of operation.
10 The duration (momentary or latched) of the Start Output in seconds.
For latched input, enter all zeros or press
11 The duration (momentary or latched) of the Early Warning output in seconds.
12 The duration (momentary or latched) of the Brake On output in seconds.
13 The duration (momentary or latched) of the Zero Speed output in seconds.
14 The duration (momentary or latched) of the Zero Speed + Delay 1 output in seconds.
15 The duration (momentary or latched) of the Zero Speed + Delay 2 output in seconds.
16 Momentary for automatic (internal) reset or latched for manual (operator) reset.
17 The delay time for Zero Speed + Delay 1 output in seconds.
18 The delay time for Zero Speed + Delay 2 output in seconds.
19 The time window in seconds to determine Zero Speed. Zero Speed equals no pulses received within window.
20 Releases latched outputs at the start command. Press 1-6 on the front panel to release or drop output.
21 Releases latched outputs at the move preset. Press 1-6 on the front panel to release output or drop output.
22 Releases latched outputs at the Early Warning signal. Press 1-6 on the front panel to release output or drop
output.
23 Releases latched outputs at reset. Press 1-6 on the front panel to release output or drop output.
24 See Serial Interface section.
25 See Serial Interface section.
26 Control identification number. See Serial Interface section.
See Diagnostic Tests on page 15 for further information on diagnostic tests listed below.
27 Front panel keyboard test.
28 Non-Volatile RAM test.
29 Control input test.
30 Control output test.
31 Front panel display test.
32 Control program memory test.
33 Displays Date Code of CBC-1000 software.
34 Control serial test.
35 Returns control to factory default settings.
RESET