Manual

6
Warner Electric • 800-825-9050 P-201 819-0485
Parts List for kit 5200-101-010
Item Quantity Part Name
11Bracket
--
21
Screw, Hex, Washer Head
and Sems Conical Washer
31Box, Conduit
43Screw, Hex, Washer Head
51Plug, Protective
62Grommet, Wire
*7
2 Spacer No. 8 Thd.
2 Spacer No. 6 Thd.
82Cap terminal
91
Screw, Hex, Washer Head,
Green
9-1 3 Terminal, Ring
10 1 Cover
11 2 Screw, No. 8 Brass
12 1 Plug, Protective
*The No. 6 spacers are required on Sizes 375, 400 and 475. All
others use No. 8.
4
10
8
11
9-1
*7
3
6
5
9
9-1
12
2
1
4
Components
Installation Instructions
Conduit box kit No. 5200-101-010 contains all
components needed to assemble a conduit box for
PB400 brake.
When properly installed, this conduit box is
designed to provide a proper means for field wiring
terminations. It conforms to the requirements of
Underwriters Laboratories.
Do not connect rigid conduit
directly to the conduit box. A minimum of 12”
of flexible liquid tight conduit or other suitable
flexible wiring with appropriate fittings is
required. Flexible wiring is required to
prevent side loading of bearing on bearing
mounted clutches and possible deformation
or breakage of the conduit box or
clutch/brake components during assembly.
Step 1
Assemble a customer supplied flexible wiring
connector into desired end of conduit box (3).
Press protective plug (5) into unused conduit hole.
Thread green washer head hex screw (9) into
round hole in base of conduit box. Place terminal
ring (9-1) over screw before inserting.
Snap two wire grommets (6) into square holes in
conduit box base. The grommet crowns should
be toward the outside of the box and the rubber
flanges should be on both sides of the conduit
box.
Push two terminal spacers (7) through rubber
grommets. Number 6 spacers fit in PB400. (See
Figure 10)
Figure 10