Manual
28 Warner Electric • +33 (0) 2 41 21 24 24
P-2097-WE-A4
8. Open Loop Conguration
The XCTRL also integrates two open loop controls. The aim of these controls is to add a linear compensation
curve and/or a simple gain factor. The Input can be a load cell, a dancer arm or other analog sensors (e.g.
Ultrasonic Sensor).
• Select the Input
Note: For all information about control Pinout and
Wiring please refer to the Typical Wiring section.
• Two types of correction are available: Linear curve and X Factor. Both can also be
combined.
• Linear Curve
Out = A*In + B
In = Input voltage selected above
A = Curve Gain (could be negative)
B = Offset
Note: The Out level will not exceed 100% of
the span dened in the Input/Output tab.
• X Factor
Out = X Factor*In
In = Input voltage selected above or A*In+B
• How to Set Coefcients A & B and X Factor Value?