IV. Hardware Pin Out
1 SD Card External interface Parameters Savings. Possibility to save up to 8 partitions.
2 USB External interface
Use to setup the controller (Input/Output, PID, splice parameters) and to up-
load and download all parameters to a setup partition.
3 A Digital IN
Splice selection inputs. Depending on the A, B, C bit state, select a congu-
ration of OUT1, OUT2, between a logical menu of 11 possibilities and select
PID1&2 compensation input
NPN, PNP input type Selectable.
4 B Digital IN
5 C Digital IN
6 Sync Digital IN
Logical input which activate the changes of the A, B, C inputs. Depending on
logical setting, it could be activate on edge or on state.
NPN, PNP input type Selectable.
7 ErrS1 Digital Out
Error signal output to inform that Sensor1/Cell1 is out of range. Working range
can be programmed in %, Kg, Nm… 0-24VDC
8 P1 Digital IN
Parameters Partition signal input. Depending on the P1, P2, P3 bit state, it
offers a selection to all parameters tables used to setup all Input/Output, PID
and Open loop controllers
NPN, PNP input type Selectable.
9 P2 Digital IN
10 P3 Digital IN
11 Stplnt Digital IN
Stop or reset the integral calculation of the PID
NPN, PNP input type Selectable.
12 ErrS2 Digital Out
Error signal output to inform that Sensor2/Cell2 is out of range. Working range
can be programmed in %, Kg, Nm… 0-24VDC
13 24V
Power supply
OUT
Auxiliary 24VDC Power supply, 100mA
14 Out1 Analog Output
Analog Output of PID1 or Open Loop 1 out depending on ABC selection.
Selectable: 0/+10V DC or 4/20mA.
15 Gnd Ground
16 Ana1 Analog Input
Auxiliary Sensor Input: usually used to compensate the PID Gain versus the
roll diameter
Selectable: 0/+10V DC or 4/20mA.
17 Gnd Ground
18 24V
Power supply
OUT
24VDC Power supply, 100 mA
19 Out2 Analog Output
Analog Output of PID2 or OL2 out depending on ABC selection.
Selectable: 0/+10V DC or 4/20mA.
20 Gnd Ground
21 Ana2 Analog Input
Auxiliary Sensor Input: usually used to compensate the PID Gain versus the
roll diameter
Selectable: 0/+10V DC or 4/20mA.
22 Gnd Ground
23 Ex1+ Power Out
Sensor power supply & Load Cell excitation
Selectable 0-10Vdc or 0-15Vdc, 100mA
24 Ex1- Power Out
25 C1+
Differential Analog
Input
Load Cell and/or Dancer Arm sensor input
0-10Vdc, 0-40mVdc
26 C1-
27 Shld Shielding Load Cell or Sensor shielding
28 Ex2+ Power Out
Sensor power supply & Load Cell excitation
Selectable 0-10Vdc or 0-15Vdc, 100mA
29 Ex2- Power Out
30 C2+
Differential Analog
Input
Load Cell and/or Dancer Arm sensor input
0-10V DC, 0-40mVdc
31 C2-
32 Shld Shielding Load Cell or Sensor shielding
This installation and Operating Manual has been arranged for the systematic installation and start-up of your
Tension Control System. Please check off each step before proceeding to the next step.