Specifications

8 UD - Operator Manual 141216
User Settings Default Selection
Power Save ON ON/OFF
Detergent Injection Time 12 5 - 30 secs
Display Contrast 27 10 - 40
User Programming
The User Settings menu is accessed for programming by pressing the UP and DOWN
keys simultaneously for a few seconds. The programming options are specified in the
table below:
Power Save function reduces the rinse temperature setting by 10°C when the machine is
idle for 5 minutes or more. The temperature settings return to the set value when door is
opened or START/STOP key is pressed.
QuickStart starts washing regardless of rinse temperature. If rinse temperature is not
sufficient cycle countdown will stop at 22 seconds. Washing continues until rinse reaches
temperature required for sanitization and countdown then resumes.
Troubleshooting
If an error message appears on the control display first try turning the machine OFF for 30
seconds and then back ON.
Display Code Cause Remedy
7. Fill Failure - wash tank
not full after fill timeout
Check drain upstand fitted Fit upstand before
filling
Check flow rate of water supply Check water supply
8. Drain Failure Drain hose jammed/blocked Check/unblock drain
hose
Drain upstand not removed Remove upstand
before draining
Keypad Start Button Colours
Machine State Colour
Door Open Purple
Filling White
Heating Orange
Ready Green
Ecopower Blue
Washing Red
Error Flashing Red
If the error message remains call for service