Chapter 6 - Operation and settings
6.5. Adjust rim cleaner pump
The volume of chemical agent required depends on
the type of chemical agent. Please follow the deter-
gent manufacturer's instructions.
)
Adjust the delivery volume at the adjusting
screw (1) at the rim cleaner pump.
The use of improper cleaning agents (such as
cleaners that contain hydrochloric acid, sul-
phuric acid, formic acid, hydrofluoric acid or ox-
alic acid) and/or incorrect mixing proportions as
well as use of undiluted cleaning agents may
cause damage to the system or the vehicles.
Use only products which are recommended for
the automatic cleaning of vehicles.
Never use the cleaning agents undiluted. Dilute
the cleaning agents as specified by the supplier.
For damages caused by using improper cleaning
agents or incorrect mixing proportions no war-
ranty claims will be accepted.
The maximum adjustable volume is 50 ml/stroke.
-+
1
NOTICE