Operating instructions

SoftCare Evo - Type SE10 7-11
Flat belt
Energy chains
System of hoses
Low-pressure water dis-
tribution
Clean the suction grids
Chapter 7 - Maintenance and care
7.3.2. Weekly Maintenance
)
Check the belts for deterioration and wear. If
there is a high degree of deterioration or wear,
i.e. the belts are frayed, ripped or fragile,
please inform WashTec Service.
Operation with damaged belts may cause serious
injury to persons or damage to the vehicle.
Pay attention to the safety instructions in
chapter 2.
)
Check all the energy chains including leads
and cables (roof brush, dryer system, etc.) for
wear and breakage. In the event of heavy
wear or breakage, please inform WashTec
Service.
)
Check the system of hoses for loose connec-
tions and leaks. Tighten any loose connec-
tions. If you find any leaks, please inform
WashTec Service.
)
Check the low-pressure water distribution for
damage and leakages. Please inform
WashTec Service in case of damages or leak-
ages.
)
Clean the suction grids of the dryer blowers.