Operating instructions

SoftCare Evo - Type SE10 8-6
Chapter 8 - Error messages
Type of failure and cause of failure – Part 2
No. Type of failure Cause of failure
039 Short-circuit, transmitter Light barrier, front
040 Wire break, transmitter Light barrier, front
041 Short-circuit, receiver Light barrier, front
042 Wire break, receiver Light barrier, front
043 Power limit reached Light barrier, front
044 Short-circuit, transmitter Light barrier, center
045 Wire break, transmitter Light barrier, center
046 Short-circuit, receiver Light barrier, center
047 Wire break, receiver Light barrier, center
048 Power limit reached Light barrier, center
049 Short-circuit, transmitter Light barrier, rear
050 Wire break, transmitter Light barrier, rear
051 Short-circuit, receiver Light barrier, rear
052 Wire break, receiver Light barrier, rear
053 Power limit reached Light barrier, rear
054 Short-circuit, transmitter Light barrier
055 Wire break, transmitter Light barrier
056 Short-circuit, receiver Light barrier
057 Wire break, receiver Light barrier
058 Power limit reached Light barrier
059 Actuated Emergency cut off
060 Actuated internally Emergency cut off
061 Safety strip activated Emergency cut off
062 No voltage X11-X13 (FC and inputs)
063 No voltage X2, X3 (24VDC outputs)
064 No voltage X5, X6 (24VDC outputs)
065 No voltage X7 (24VDC outputs)
066 No voltage Px, control voltage
067 Fuse tripped Motor protection, rotation
068 Fuse tripped Motor protection, feed
069 Fuse tripped Motor protection, blower
070 Cable or electronics Power measurement
071 Power limit reached Power measurement
072 Short-circuit, overload Power measurement
073 No measured value Power measurement
074 Tank empty Shampoo
075 Tank empty Drying aid
076 Tank empty Wax