Specification

Watco Manufacturing Company
INSTALLATION INSTRUCTIONS
500 Series, TRIP LEVER type, ADS or PVC Pipe
600 Series, TRIP LEVER type, ADS or PVC Pipe
501/502 Series, TRIP LEVER 17
& 20 Gauge Brass Pipe
1. See reverse side for Trip Lever variations. Apply plumber’s putty"" around bottom side of strainer body
flange. Insert strainer body through drain hole in bottom of tub. Place drain ell gasket on drain ell on,
outside of tub. Thread Strainer body into drain ell. Use strainer body tool or pliers handles to tighten.
Remove excess putty.
2. Slide slip nut, then plastic or brass washer (ferrule) onto drain ell. Make sure thick side of washer is
toward nut Slide
tee onto drain tube and partially tighten nut
3. Place overflow washer on overflow ell. Slide slip nu~ then plastic or brass washer (ferrule) on~ overflow
drain ell. Insert into tee. Adjust so that overflow ell is snug against overflow hole in tub and long portion of
tee is vertical with floor. Hand tighten both nuts as much as possible, then another 1/8 turn with wrench.
NOTE: If the bass ferules are used joints can be soldered. DO NOT solder if plastic washers are used.
4. Start the two retainer plate screws in the bottom two holes in the overflow ell. Hang the retainer plate over
the screw heads and tighten the screws until the retainer plate makes contact with the interior tub will.
5. Install overflow plate and drop cylinder assembly, (see variations on reverse side) with screws provided.
6. Adjust drop cylin4er assembly to insure no leaks to drain when enclosed position
**CAUTION: Avoid contact of plumber putty with
ABS plastic parts

Summary of content (2 pages)